When can a battery power station replace a site generator?

A battery power station stores energy in a battery and gives out 230 V with no exhaust, so it can work indoors where a petrol generator must not. TSR’s Staring STI-E2400 delivers 2400 W continuous from 2160 Wh. Divide the capacity by the connected load for the running time, and expect a little less. For several working days without charging, a generator is still the tool.

STAT

A few minutes of petrol powered equipment, such as a generator or cut-off saw, running indoors or in a trench can create carbon monoxide levels that can kill, HSE warns on its construction guidance, updated 7 November 2024. Source: HSE, Carbon monoxide

Key takeaways

Topic In brief
Indoors No exhaust gases, so a battery station can run inside. A petrol generator cannot.
Runtime Capacity in Wh ÷ combined load in W. Losses make it a little shorter.
Output Stay under the continuous rating. Peak covers start-up only.
Charging Mains, car charger or solar panel. Usable while charging.
Limit Several working days without charging is generator work.

What is a battery power station?

A battery power station is a battery, an inverter and a set of sockets in one portable case. It stores energy and converts it into 230 V alternating current for tools, lights and chargers.

TSR stocks two Staring models. The STI-E2400 holds 2160 Wh in a 48 V LiFePO₄ battery and gives 2400 W continuous through three 230 V IP44 sockets, plus USB-A, USB-C and DC outputs. The STI-E1200 holds 1152 Wh at 25.6 V and gives 1200 W through two 230 V sockets.

Both produce a pure sine wave. TSR’s product pages note that this suits measuring instruments, computers and modern chargers.

Why does a petrol generator not belong indoors?

Exhaust. A petrol engine makes carbon monoxide, a gas you cannot see or smell. HSE lists petrol powered equipment such as generators and cut-off saws used indoors or in enclosed spaces, trenches and excavations included, among the site tasks where dangerous levels occur. Even after a few minutes, it says, the level can kill.

HSE’s control advice, on its page updated 7 November 2024, starts with prevention: use safer alternatives, such as electrical tools, where you can. Petrol equipment should never run indoors or in an enclosed space unless the ventilation needs have been fully assessed. Petrol generators go outside, in well ventilated spaces where fumes cannot drift into building openings.

The risk is not theoretical. In October 2023 Technical Safety BC published its investigation into a death in Sparwood, British Columbia. A worker was found unresponsive inside a house under construction, with a portable petrol generator and dangerously high carbon monoxide levels. Despite the warning label against indoor use, evidence suggested the generator had powered construction work and a space heater inside the enclosed house.

Early symptoms are easy to dismiss. HSE notes they can be confused with flu, food poisoning or simple tiredness: drowsiness, headaches, breathlessness and nausea.

A battery power station removes the engine from the room. TSR’s pages state that the Staring units produce no exhaust gases, so they can also be used indoors.

How long will a battery power station run?

TSR’s method is simple. Divide the battery capacity in watt-hours by the combined power of the connected devices in watts. The answer is the running time in hours. Conversion losses in the inverter make the real figure slightly shorter, so treat the result as an upper limit.

Combined load STI-E1200 (1152 Wh) STI-E2400 (2160 Wh)
300 W about 3.8 h about 7.2 h
500 W about 2.3 h about 4.3 h
1000 W about 1.2 h about 2.2 h
1200 W about 1.0 h about 1.8 h
2400 W over the rating about 0.9 h

These are capacity divided by load, before losses. Add up what will actually run at the same time, not every plug on the list.

Peak output is a separate number. The STI-E2400 gives 3500 W peak and the STI-E1200 gives 2000 W, which TSR describes as brief headroom when devices start up. It does not raise the continuous rating. TSR’s safety line on both pages is direct: do not exceed the continuous output.

STI-E1200 or STI-E2400?

STI-E1200 STI-E2400
Continuous / peak 1200 W / 2000 W 2400 W / 3500 W
Battery 25.6 V, 1152 Wh, LiFePO₄ 48 V, 2160 Wh, LiFePO₄
230 V sockets 2 3 (IP44)
Full charge about 2 h about 3 h
Weight 15.6 kg 25 kg
Size (L x H x W) 59 x 38 x 36 cm 59 x 42.5 x 36 cm

The STI-E1200 is the one to carry. At 15.6 kg it moves easily from the van to the workstation, and TSR pitches it at hand tools, electronic equipment and battery charging in service and installation work.

The STI-E2400 has twice the continuous output, nearly twice the energy and a third socket. TSR names hand tools, battery chargers and lights as its work. The three 230 V sockets are rated IP44; our post on IP ratings for site equipment explains what the rating means.

How is a battery power station charged on site?

Three ways, on both models: from 230 V mains, from a car charger, or from a solar panel. From empty, a full mains charge takes about three hours on the STI-E2400 and about two hours on the STI-E1200, per TSR’s pages.

Both can run and charge at the same time. In mobile work, as TSR puts it, the job continues even while the battery is on charge. TSR’s pages add one rule for the battery side: follow the manufacturer’s instructions for charging and storage.

When is a generator still the right choice?

When the energy runs out before the work does. A battery station holds a fixed amount of energy, and the table above shows how fast a heavy load spends it. TSR’s own advice on the STI-E2400 page is plain: if you need several working days without charging, look at the generator range.

A practical split follows the building. Indoors, in an enclosed room or a trench where exhaust can gather, the battery unit does the work. Outside, in open air and away from openings as HSE asks, a generator runs the heavier and longer loads. If a generator feeds the site, our posts on how a generator-fed supply is earthed and on generator load management cover the next steps.

One thing a portable station is not: a fixed supply for a building. TSR’s pages state that the unit is not connected to a building’s installation without a qualified electrician.

Battery station check before the shift

  • List the loads. Add the watts of what runs at the same time.
  • Check the rating. The total stays under 1200 W or 2400 W continuous.
  • Estimate the time. Wh ÷ W, then allow a little less for losses.
  • Plan the charge. Mains, vehicle or solar, about 2 or 3 hours from empty.
  • Check the leads. TSR asks for extension cables to be checked before use.
  • Keep engines out. Any petrol unit that stays goes outside, away from openings.
  • No hard-wiring. Connection to a building’s installation needs a qualified electrician.

Summary

A battery power station puts 230 V where a petrol engine must not run: indoors, in enclosed rooms and in trenches. Size it by continuous output, estimate its time as capacity divided by load, and charge it from mains, a vehicle or a solar panel between or during use. When the job needs days of power without a charge, a generator outside is still the answer. TSR’s Staring STI-E2400 and STI-E1200 can be added to the quotation basket. Tell us which devices you plan to use and for how long.

Frequently asked questions (FAQ)

Can a battery power station be used indoors?

Yes. TSR’s Staring units produce no exhaust gases, so they can also be used indoors. HSE advises safer alternatives such as electrical tools where you can, instead of petrol equipment in enclosed spaces.

How long does a 2400 W battery power station run?

Divide 2160 Wh by the combined load. At 500 W that is about 4.3 hours, at the full 2400 W about 54 minutes. Conversion losses make the real time slightly shorter.

What does the peak output figure mean?

It is brief headroom when a device starts up: 3500 W on the STI-E2400 and 2000 W on the STI-E1200. Running loads must stay under the continuous rating.

How long does charging take?

About three hours from empty for the STI-E2400 and about two hours for the STI-E1200, from mains. Both also charge from a car charger or a solar panel, and both work while charging.

Can I connect a battery power station to a building’s wiring?

Not yourself. TSR’s pages state the unit is not connected to a building’s installation without a qualified electrician.

When should I use a generator instead?

When the work needs several days of power without charging, or loads beyond the continuous rating. The generator then runs outside in a well ventilated place, as HSE advises.