ESE 100 IW/RS generator – 94 kVA / 75.2 kW diesel 3-phase
Product code (SKU): E335277ESE 100 IW/RS generator – 94 kVA / 75.2 kW diesel 3-phase
Outlets: 1 x CEE 63 A, 1 x CEE 32 A, 1 x CEE 16 A, 1 x CEE 230 V/16 A, 1 x Schuko 230 V/16 A.
Endress ESE 100 IW/RS is a 1500 rpm synchronous generator with a continuous output of 94 kVA / 75.2 kW. It has AVR voltage regulation, a Stage V engine and an extended fuel tank.
ESE 100 IW/RS is a 1500 rpm synchronous generator for continuous use in industry, construction and standby power systems. Its continuous output (PRP) is 94 kVA / 75.2 kW. The engine meets the EU Stage V emission standard.

Add the product to the quotation basket and send your request – we confirm availability and delivery time at the same time.
ESE 100 IW/RS – features
- Continuous output (PRP) 94 kVA / 75.2 kW, 400/230 V, 50 Hz
- Rated current 135.8 A (3~)
- FPT F36ETVP03.A94 diesel engine, 3600 cm³, water-cooled, Stage V
- AVR voltage regulation and electronic speed control, frequency accuracy ±1 %
- Consumption 15.5 l/h and running time 27.1 h at 75 % load, extended fuel tank
- Outlets: CEE 400 V 63 A, 32 A and 16 A, CEE 230 V/16 A and Schuko 230 V/16 A
- IP54-rated manual/automatic control panel with a remote start connection
- Sound-insulated, galvanised housing
- Base frame for forklift handling, impact protection and a liquid collecting tray
Why 1500 rpm suits continuous use
The generator runs at 1500 revolutions per minute. The slower speed means lower noise and vibration, as well as a longer service life and service interval.
Therefore, the model suits sites where the unit runs for days on end. Examples include the main supply of a worksite, industrial shutdowns and standby power for critical systems.
Meanwhile, AVR regulation keeps the voltage constant even when the load varies. The ±1 % frequency accuracy matters for sensitive devices and three-phase loads.
ESE 100 IW/RS for long running periods
With the extended fuel tank, the running time is 27.1 hours at 75 % load.
The 230 V / 16 A battery charging connection keeps the starter battery charged during idle periods. In addition, preparation for coolant preheating improves starting in frost.
The water separator in the diesel filter protects the engine. The oil drain pump makes oil changes easier, and the main switch makes servicing safer.
Sizing and comparison with other models
Size the generator so that the continuous load stays below the PRP output. Also allow for the starting currents of motor loads, which are briefly much higher.
This is the most powerful model in the 1500 rpm range. If 54 kVA is enough, the ESE 60 IW/RS uses 8.15 l/h at 75 % load. For needs below 45 kVA, see for example the ESE 45 YW/RS with a Yanmar engine.
ESE 100 IW/RS in worksite power distribution
The largest CEE 63 A outlet is suited to feeding site distribution, for example a plug-on sub-distribution board. The smaller 32 A and 16 A outlets and the 230 V sockets serve equipment directly.
You can find all slow-running models in our generator range.
Safety
On the ESE 100 IW/RS, overload protection, guarding of hot engine parts and a main switch are standard. Furthermore, the liquid collecting tray stops oil and fuel leaks from spreading to the ground.
Engine exhaust contains toxic carbon monoxide. Therefore, run the generator only outdoors or in a well-ventilated place where exhaust cannot enter buildings.
Follow the manufacturer’s instructions for earthing and connections. In addition, refuel only when the engine is switched off.
Connecting the generator to a building’s electrical installation is always a job for a qualified electrician. The requirements for electrical work are explained on the Tukes website.
ESE 100 IW/RS – technical data
| Continuous output (PRP) | 94 kVA / 75.2 kW |
| Engine continuous output (PRP) | 85.5 kW |
| Rated voltage | 400/230 V, 50 Hz |
| Rated current 3~ (PRP) | 135.8 A |
| Alternator | Synchronous |
| Voltage regulation | AVR, frequency accuracy ±1 % |
| Engine | FPT F36ETVP03.A94, Stage V |
| Displacement | 3600 cm³ |
| Cooling | Water |
| Speed | 1500 r/min, electronic control |
| Fuel | Diesel |
| Consumption at 75 % load | 15.5 l/h |
| Running time at 75 % load | 27.1 h |
| Starting | Electric, 12 V |
| Sound power level LWA | 97 dB(A) |
| Sound pressure level LPA (7 m) | 72 dB(A) |
| Sockets | 1 x CEE 400 V/63 A, 1 x CEE 400 V/32 A, 1 x CEE 400 V/16 A, 1 x CEE 230 V/16 A, 1 x Schuko 230 V/16 A |
| Control | IP54 manual/automatic panel, remote start connection |
| Product number | E335277 |
Frequently asked questions
How long does the ESE 100 IW/RS run on one tank?
At 75 % load, the running time is 27.1 hours. Consumption is then 15.5 litres per hour.
Which outlets does the generator have?
It has CEE 400 V outlets of 63 A, 32 A and 16 A. There are also CEE 230 V/16 A and Schuko 230 V/16 A.
Can the generator be started remotely?
Yes. The IP54-rated manual/automatic panel and remote start connection allow local or remote control.
What is the product number?
The product number (MPN) is E335277. Use it in quotation requests.
Request a quote
Add the product to the quotation basket and send your request. Tell us the site loads, the expected running time and the supply method. We can combine the generator, extension cables and distribution boards in the same quote.