ESE 60 IW/RS generator – 54 kVA / 43.2 kW diesel 3-phase
Product code (SKU): E335276ESE 60 IW/RS generator – 54 kVA / 43.2 kW diesel 3-phase
Outlets: 1 x CEE 63 A, 1 x CEE 32 A, 1 x CEE 16 A, 1 x 230 V/16 A, terminal block.
Endress ESE 60 IW/RS is a 1500 rpm synchronous generator with a continuous output of 54 kVA / 43.2 kW. It has a Stage V diesel engine, a sound-insulated galvanised housing and an IP54 manual/automatic control panel.
ESE 60 IW/RS is a 1500 rpm synchronous generator for continuous professional use in industry, construction and standby power. Its continuous output (PRP) is 54 kVA / 43.2 kW. The FPT diesel engine meets the Stage V emission standard.

Add the product to the quotation basket and send your request – we confirm availability and delivery time at the same time.
ESE 60 IW/RS – features
- Continuous output (PRP) 54 kVA / 43.2 kW, 400/230 V, 50 Hz
- Rated current 78 A (3~)
- FPT F34TEV1PV.S550 diesel engine, 3400 cm³, water-cooled, Stage V
- Electronic speed control (CR)
- Consumption 8.15 l/h and running time 31.9 h at 75 % load
- Outlets: CEE 400 V 63 A, 32 A and 16 A, 230 V/16 A and a terminal block
- IP54-rated manual/automatic control panel with a remote start connection
- Sound-insulated, galvanised housing
- Base frame for forklift handling, impact protection and a liquid collecting tray
Quiet and economical 1500 rpm running
The 1500 rpm operating speed keeps the noise level and wear low. As a result, the service interval is longer than on 3000 rpm models.
The sound pressure level is 69 dB(A) at 7 m.
Consumption is 8.15 litres per hour at 75 % load, and the running time is 31.9 hours.

ESE 60 IW/RS for demanding conditions
The galvanised housing improves corrosion resistance and extends the service life. The base frame withstands continuous forklift handling, and impact protection guards the unit on busy sites.
Preparation for coolant preheating ensures reliable starting in a cold climate. In addition, the 230 V / 16 A battery charging connection keeps the unit ready after long idle periods.
Standard equipment includes a diesel filter with water separator, an oil drain pump and a main switch. Together they make servicing easier and keep the engine in good condition.
Sizing: 42, 54 or 94 kVA?
Choose a model so that the continuous load stays below the PRP output. Also leave headroom for the starting currents of motor loads.
If 42 kVA is enough, the ESE 45 YW/RS uses 7.4 l/h. For larger sites, the ESE 100 IW/RS has a continuous output of 94 kVA.
The terminal block is used for fixed connections when the load is not fed from sockets. These connections are made by a qualified electrician.
ESE 60 IW/RS in worksite power distribution
The CEE 63 A outlet can feed a plug-on sub-distribution board. For longer distances, use a 63 A extension cable.
You can find other slow-running models in our generator range.
Safety
On the ESE 60 IW/RS, overload protection, guarding of hot engine parts and a main switch are standard. Furthermore, the liquid collecting tray catches any oil or fuel leaks.
Engine exhaust contains toxic carbon monoxide. Therefore, run the generator only outdoors or in a well-ventilated place where exhaust cannot enter buildings.
Follow the manufacturer’s instructions for earthing and connections. In addition, refuel only when the engine is switched off.
Connecting the generator to a building’s electrical installation is always a job for a qualified electrician. The requirements for electrical work are explained on the Tukes website.
ESE 60 IW/RS – technical data
| Continuous output (PRP) | 54 kVA / 43.2 kW |
| Engine continuous output (PRP) | 54 kW |
| Rated voltage | 400/230 V, 50 Hz |
| Rated current 3~ (PRP) | 78 A |
| Alternator | Synchronous |
| Voltage regulation | Electronic |
| Engine | FPT F34TEV1PV.S550, Stage V |
| Displacement | 3400 cm³ |
| Cooling | Water |
| Speed | 1500 r/min, electronic control (CR) |
| Fuel | Diesel |
| Consumption at 75 % load | 8.15 l/h |
| Running time at 75 % load | 31.9 h |
| Starting | Electric, 12 V |
| Sound power level LWA | 94 dB(A) |
| Sound pressure level LPA (7 m) | 69 dB(A) |
| Sockets | 1 x CEE 400 V/63 A, 1 x CEE 400 V/32 A, 1 x CEE 400 V/16 A, 1 x 230 V/16 A, terminal block |
| Control | IP54 manual/automatic panel, remote start connection |
| Product number | E335276 |
Frequently asked questions
How long does the generator run on one tank?
At 75 % load, the running time is 31.9 hours and consumption is 8.15 litres per hour.
Which outlets does the generator have?
It has CEE 400 V outlets of 63 A, 32 A and 16 A. There is also a 230 V/16 A socket and a terminal block.
How does the ESE 60 IW/RS differ from the ESE 100 IW/RS?
The continuous output is 54 kVA here and 94 kVA on the larger model. Consumption at 75 % load is 8.15 l/h and 15.5 l/h.
What is the product number?
The product number (MPN) is E335276. Use it in quotation requests.
Request a quote
Add the product to the quotation basket and send your request. Tell us the site loads, the running time and whether a terminal block connection is needed. We can combine the generator, extension cables and distribution boards in the same quote.