Sub cabinet 160 A
Sub cabinet 160 A
The 160A site substation is made of powder-coated and corrosion-resistant 2 mm aluminium. The solid structure of the cabinet withstands hard handling on site. The cabinet is equipped with lifting eyes, a stand designed for the truck and has lockable doors.
Sub cabinet 160 A – the 160A site substation is made of powder-coated and corrosion-resistant 2 mm aluminium. The solid structure of the cabinet withstands hard handling on site. The cabinet is equipped with lifting eyes, a stand designed for the truck and has lockable doors.

Sub cabinet 160 A on the worksite
The distribution board is the site’s outlet point: power for hand tools, lighting and dryers is taken from it. It is placed close to the work so that extension cords stay short.
Boards are added as the site grows. The whole is worth planning in advance so that the supply is sufficient for all of them.
This model is rated 160 A. Size the equipment by the actual simultaneous load – the sum of the nameplate ratings almost always leads to oversizing.
Outputs: 3 x 16A (230V), 3 x 16 A, 2 x 32A, 2 x 63A. Count the work points before choosing – the number of outputs decides how many machines one board can feed.
Where Sub cabinet 160 A is used
Typical sites are construction projects, renovations, industrial maintenance and event power. What they share is that the electrical supply is temporary and the conditions are demanding.
Temporary does not mean lighter requirements. Site equipment is exposed to dust, moisture, moving and mechanical stress in a way that fixed installations never are.
Check the load distribution between phases during use. Uneven distribution overloads one phase while the others run half empty, and the usual symptom is a fuse that keeps tripping.
Sub cabinet 160 A – how to choose the right model
The equipment is chosen by rated current and outputs. Start by calculating the simultaneous load and the output types needed, and choose the model on that basis.
Other models of the same type are Temporary power supply subcabinet 250 A, Sub cabinet TAK 125A KS, Sub cabinet TAK 63 A KS, Subcabinet TAK 32A, Subcabinet TAK 32A.
Other details that affect the choice: protection class IP44, short-circuit withstand Icf = 25 kA, RCD 30 mA ja 300 mA, supply cable 1×95-240, weight 77 kg. These are worth checking already at the quotation stage.
You can see the full range in the product group, and read about real-time monitoring on the Spine page.
Practical notes for use
Winter brings requirements of its own. Condensation forms when cold equipment is brought into the warm, and moisture inside the enclosure is a common reason for an RCD tripping with no visible cause.
Mark the equipment with the site details and keep a record of what is fed from where. On a site with several contractors that saves time at every fault-finding.
RCD protection is mandatory for socket outputs on a site. Its operation is tested with the test button at commissioning and at regular intervals afterwards.
Sub cabinet 160 A – installation and maintenance
Installation and connection work is carried out by a qualified electrician. The equipment must be made dead before connection work, and the absence of voltage verified by measurement.
Place the equipment on level ground and so that it can be reached freely even when the site fills up with material. Material stacked in front blocks both use and emergency isolation.
Test the RCD with its test button at commissioning and at regular intervals afterwards. The test takes a second and is still almost always forgotten.
The unit weighs 77 kg. Take the weight into account when moving and lifting – damage is most often caused during transport, not in use.
Check the joints and fixings regularly during use. A joint that heats up is a sign of a fault and should be corrected before the fault spreads.
Safety and inspections
Site electrical installations are subject to the same requirements as fixed installations, and some of them are stricter. The equipment has to withstand moving, dust, moisture and mechanical stress for the whole project.
The installation is inspected at commissioning and regularly during use: enclosure, joints, the operation of the protective devices and the fact that live parts cannot be reached.
Damaged equipment is not repaired improvised on site. A cracked enclosure, a burnt terminal or a damaged socket is replaced – on a site a temporary repair almost always becomes permanent.
Document the configuration and any changes made. Up-to-date information on outputs and protection speeds up fault-finding and the next inspection.
Delivery and sizing help
We deliver the equipment together with the cables and the rest of the site power supply in one delivery, so the set is complete when it arrives on site.
Describe the whole site in your request for quotation: supply power, the outputs needed and the estimated length of the project. We size the set on that basis.
We also help with the sizing. If you are unsure about the size or the number of outputs, ask us – equipment sized wrong costs more than equipment chosen right the first time.
Sub cabinet 160 A – technical data
| Rated current | 160 A |
| Rated voltage | 400 V (50 Hz) |
| Supply fuse | NH00 160 A |
| Supply cable size | 1×95-240 |
| Fixed output | 1 x SLK 160 NH00 160A |
| Sockets | 3 x 16A (230V), 3 x 16 A, 2 x 32A, 2 x 63A |
| Residual current device (RCD) | 30 mA ja 300 mA |
| Short-circuit withstand | Icf = 25 kA |
| Current transformer | 200/5 0,2S |
| Protection class | IP44 |
| Dimensions (H×W×D) | 1239×1163×405 mm |
| Weight | 77 kg |
| Approvals | CE |
Frequently asked questions
What is the rated current of Sub cabinet 160 A?
The rated current is 160 A.
What outputs does the product have?
Outputs: 3 x 16A (230V), 3 x 16 A, 2 x 32A, 2 x 63A.
Does the product have an RCD?
Residual current device (RCD): 30 mA ja 300 mA.
What is the protection class?
Protection class: IP44.
What is the short-circuit withstand?
Short-circuit withstand: Icf = 25 kA.
What are the dimensions?
Dimensions: 1239×1163×405 mm.
How much does the product weigh?
Weight: 77 kg.
What supply cable is needed?
Supply cable: 1×95-240.
What approvals does the product have?
Approvals: CE.
Who may install the product?
Installation is carried out by a qualified electrician. The requirements are explained in more detail on the Tukes website.
The requirements for electrical installations on worksites are explained in more detail on the Tukes website.
Request a quotation
Add to the quotation basket and send us your request – we will confirm availability and delivery time at the same time. You can see the full range in the product group.
Technical information
| Nominal Current | 160 A |
|---|---|
| Nominal voltage | 400 V (50 Hz) |
| Supply fuse | NH00 160 A |
| Size of the input cable | 1 x 95-240 |
| Fixed outlet | 1 x SLK 160 NH00 160 A |
| Sockets | 3 x 16A (230V), 3 x 16A, 2 x 32A, 2 x 63A |
| RCD | 30 mA / 300 mA |
| Short-circuit resistance | Icf = 25 kA |
| Current transformer | 200/5 0,2S |
| Enclosure class | IP44 |
| Approvals | CE |
| Body material thickness | 2 mm |
| Dimensions (H x W x D) | 1239 x 1163 x 405 mm |
| Weight | 77 kg |