16A splitter 1×16A + 2×16A/230V for site use
16A splitter 1×16A + 2×16A/230V for site use
16A splitter with one three-phase outlet and two 230 V outlets. IP44 protection, PCE components, made in the EU.
Splitter 1×16A + 2×16A/230V is a compact and durable 16A splitter for worksite conditions. It takes its supply through a 1 m cord with a 16A plug.

Add the product to the quotation basket and send your request – we confirm availability and delivery time at the same time.
Splitter 1×16A + 2×16A/230V – features
- One 16A socket and two 16A/230V sockets, all IP44
- 1 m H07RN-F 5×1.5 mm² cord
- Voltage 400V/230V 50Hz
- Mounting hole for hanging
- Operating temperature –25 °C to +40 °C
- PCE sockets and plugs
- ABS body, weight 0.95 kg
- Made in the EU
One three-phase outlet and two 230 V outlets
The Splitter 1×16A + 2×16A/230V has one 16A socket and two 16A/230V sockets, all IP44. So one point feeds a larger machine with three-phase power as well as hand tools on 230 V.
Mounting hole makes hanging easy
The mounting hole lets you hang the Splitter 1×16A + 2×16A/230V on a wall, for example. However, never leave it hanging by the cord alone.
The operating temperature is –25 °C to +40 °C, so the splitter is reliable all year round.
Quality components, made in the EU
The splitter uses high-quality PCE sockets and plugs for long and reliable service, even in demanding conditions. On a site, always connect it to a socket with 30 mA RCD protection.
It suits sites where one 16A supply must feed a three-phase outlet and two ordinary 230 V sockets. For example, these feed hand tools and lighting.
Splitter 1×16A + 2×16A/230V in practice on site
With the splitter, one supply point gives several outlets without a separate board. So it is the fastest way to add work points where the board is far away.
Divide the loads evenly between the outlets. However, the total current of all outlets passes through the same supply connector, so the splitter adds no power.
The splitter has no RCD. Instead, protection comes from the feeding board or from a separate RCD adapter.
How to choose the right model
First, the choice starts from the size of the supply point. Take the size that matches the most common supply point on your site, so you need the fewest adapters.
Also think about how many splitters the site needs at once. After all, one unit next to the board is not enough when work points are on several floors.
Finally, you can see the full range in the electrical accessories product group.
Compatibility with other equipment
The accessory is part of a set, so choose it together with the other site equipment. When the connectors match the boards and extension cables, you need no extra adapters.
Generally, the supply comes from a site sub-distribution board. See also the plug-on sub-distribution boards and the matching extension cables. For RCD protection, see the RCD adaptor 16A/30mA.
Splitter 1×16A + 2×16A/230V – safety
On a site, people connect and disconnect cables every day. Moreover, connection points are the most common fault spot. Therefore, check the accessory as carefully as the board.
Before every use, check the enclosure for cracks, the connectors for burn marks and the cable for crush damage. Replace a damaged unit completely, because the IP rating no longer applies if the casing is broken.
Finally, only a qualified electrician may do fixed installations and repairs. You can read more about the requirements on the Tukes website.
Splitter 1×16A + 2×16A/230V – technical data
| Supply | 16A |
| Outlets | 1 x 16A, 2 x 16A/230V |
| Voltage | 400V/230V 50Hz |
| Cord length | 1 m |
| Cable | H07RN-F 5×1.5 mm² |
| IP rating | IP44 |
| Material | ABS |
| Weight | 0.95 kg |
Frequently asked questions
Can I use the Splitter 1×16A + 2×16A/230V outdoors?
Yes. IP44 protects it against dust and splashing water, and the operating temperature range is –25 °C to +40 °C.
Can I hang the splitter on a wall?
Yes. The body has a mounting hole for hanging. However, never leave the unit hanging by the cord alone.
Which socket should I connect the splitter to?
Always to a socket with 30 mA RCD protection.
What cord does the splitter have?
The cord is H07RN-F 5×1.5 mm². Check the cord and its strain relief before every use.
Request a quote
Add the product to the quotation basket and tell us how many splitters and what other site equipment you need.
Technical information
| Input | 16A |
|---|---|
| Output | 1 x 16A, 2 x 16A/230V |
| Voltage | 400V/230V |
| Frequency [Hz] | 50 Hz |
| Enclosure class | IP44 |
| Connecting cable | H07RN-F 5×1,5mm² |
| Connection cable lenght | 1 m |
| Operating temperature | -25…+40 °C |
| Material | ABS |
| Weight | 0,95 kg |