Connector 35-240mm incl. mounting plate
Connector 35-240mm incl. mounting plate
Universal cable lug for 35-240 mm² cables with an M12 bolt size. The mounting plate is included.
The Connector 35-240mm is a universal cable lug for cables of 35-240 mm². The bolt size is M12, and the delivery includes a mounting plate.

Add the product to the quotation basket and send your request – we confirm availability and delivery time at the same time.
Connector 35-240mm – features
- Universal cable lug for modular distribution boards
- Cable size 35-240 mm²
- Bolt size M12
- Mounting plate included
Where the Connector 35-240mm is used
The cable lug fits 35-240 mm² cables. As a result, one connector covers a wide size range of conductor joints.
It suits worksites and installations that need a reliable cable lug joint on an M12 bolt.
The mounting plate works as the base of the connector. It holds the connector in place and at the right distance from the busbar. Because the plate comes in the same delivery, you do not order it separately.
Part of a modular distribution board
Modules attach to the rail system of the board. As a result, you can change the configuration as the site progresses, without rewiring.
The foundation phase needs different power than the interior phase. Therefore, you swap modules instead of buying a new board. In a rental fleet, the same frame also moves from site to site. For smaller cables, the same range also has the Connector 6-95mm incl. mounting plate.
See the full range of modular distribution boards and modules. Ready boards with plug supply are in the plug-on sub-distribution boards group.
Connector 35-240mm – installation and maintenance
A qualified electrician carries out the installation and any changes. First, make the board dead, and then verify this by measurement.
A poor joint does not show from the outside. However, it heats up under load, and the heat damages first the insulation and then the busbar.
Check the joint after the first day under load and regularly after that. An aluminium conductor needs more frequent checks than copper, because aluminium creeps under tightening.
Also clean the conductor end before connecting. Use contact compound for aluminium if the manufacturer says so, since an oxidised surface raises the contact resistance.
Safety
Site electrical installations must meet the same requirements as fixed ones, and some are stricter. For this reason, inspect the board at commissioning and regularly during use.
The inspection covers the enclosure, the joints and the protective devices. It also confirms that nobody can reach live parts.
Do not repair a damaged part on site. Instead, replace a burnt connector or a cracked enclosure, because a temporary repair on site almost always becomes permanent.
The requirements for electrical work are explained on the Tukes website.
Connector 35-240mm – technical data
| Cable size | 35-240 mm² |
| Bolt size | M12 |
| Includes | Mounting plate |
Frequently asked questions
Which cable size does the connector fit?
35-240 mm² cables.
What is the bolt size?
M12.
Is the connector suitable for aluminium cable?
Check the connector markings first. Aluminium cable needs a connector approved for it, so ask us before ordering if you are unsure.
Is the mounting plate included?
Yes, this connector includes the mounting plate.
Request a quote
Add the product to the quotation basket and send your request – we confirm availability and delivery time at the same time.
Tell us the cable sizes and the number of joints. We then confirm the right connectors in one quotation.