Spine Plug & Play 125A
Product code (SKU): 501310007Spine Plug & Play 125A
Spine Plug & Play 125A connects the site’s electrical board to the Spine cloud service without any separate installation work. The enclosure comes with the current transformers and antenna pre-wired, and setup is done with the QR code on the enclosure.
- Rated current 125A, rated voltage 400 V
- Connects between the board and the supply cable with an extension socket and plug
- 50 cm 5×50 H07RN-F cables at both ends
- Weight 4 kg, dimensions 25.5 x 18 x 11 cm
- Setup with a QR code, no separate programming
Spine Plug & Play 125A is a simple way to connect a worksite electrical board to the Spine cloud service. The unit plugs in between any 125A board — regardless of make — and its supply cable, and requires no fixed installation or board replacement.

Who is Spine Plug & Play 125A for?
The unit suits sites where you want to track a 125A board’s power consumption and load in real time without modifying the board itself. Typical use cases are construction sites, events and other temporary electrical connections, where metering needs to be up and running quickly and later moved to a different site.
Metering without a fixed installation
The enclosure contains the Spine One central unit, pre-wired current transformers and an antenna. 50 cm 5×50 H07RN-F cables run from both ends of the enclosure, terminated with an extension socket and plug. The unit connects directly between the board and the supply cable, so no separate electrical installation or opening of the board is needed — metering is ready to use as soon as it’s plugged in.
What Spine Plug & Play 125A measures and alerts on
The Spine cloud service lets you monitor, in real time, power consumption, CO₂ emissions, load distribution between phases and any voltage drop, among other things. Proactive alarms can be set up in the service so that deviations are caught before they turn into a problem on site.
Spine Plug & Play 125A – technical data
- Rated current: 125A
- Rated voltage: 400 V
- Cables: 50 cm 5×50 H07RN-F at both ends
- Weight: 4 kg
- Dimensions: 25.5 x 18 x 11 cm
Does this model suit your site? Add the product to the quote cart at the top of the page to get a quote.
Setup with a QR code
Setup is done using the QR code on the enclosure. The unit can be named in the Spine cloud service with any name or ID number, and it places itself in the correct spot on the riser diagram based on the details entered during setup. When you move to a new site, simply unplug the unit and move it as-is to the next board.
Spine Plug & Play 125A is part of the Spine cloud service
All measurement data travels through the unit’s antenna to the Spine cloud service, where it’s visible in real time from any device. The same cloud service brings together all of a site’s Spine units into a single view, even when there are several boards and metering points.
Spine Plug & Play 125A on the worksite
Spine is a remote monitoring system. Measurement data is sent to the cloud service where it can be viewed on any device – nobody needs to travel to the site to read a meter.
The service shows electricity consumption, load distribution between phases, voltage drop and CO₂ emissions, among others. Predictive alarms can be set so a deviation is caught before it stops the work.
The same cloud service gathers every Spine unit on the site into one view, however many measuring points there are.
This model is rated 125 A. Size the equipment by the actual simultaneous load – the sum of the nameplate ratings almost always leads to oversizing.
Where Spine Plug & Play 125A is used
Typical sites are construction projects, renovations, industrial maintenance and event power. What they share is that the electrical supply is temporary and the conditions are demanding.
Temporary does not mean lighter requirements. Site equipment is exposed to dust, moisture, moving and mechanical stress in a way that fixed installations never are.
Check the load distribution between phases during use. Uneven distribution overloads one phase while the others run half empty, and the usual symptom is a fuse that keeps tripping.
Spine Plug & Play 125A – how to choose the right model
The equipment is chosen by rated current and outputs. Start by calculating the simultaneous load and the output types needed, and choose the model on that basis.
Other models of the same type are Spine Plug & Play 16A, Spine Plug & Play 32A, Spine Plug & Play 63A, Spine for 16A-1250A centers with fixed input, 250A Main switch module Spine.
Other details that affect the choice: weight 4 kg, dimensions 25,5 x 18 x 11 cm. These are worth checking already at the quotation stage.
You can see the full range in the product group, and read about real-time monitoring on the Spine page.
Spine Plug & Play 125A – practical notes for use
Winter brings requirements of its own. Condensation forms when cold equipment is brought into the warm, and moisture inside the enclosure is a common reason for an RCD tripping with no visible cause.
Mark the equipment with the site details and keep a record of what is fed from where. On a site with several contractors that saves time at every fault-finding.
RCD protection is mandatory for socket outputs on a site. Its operation is tested with the test button at commissioning and at regular intervals afterwards.
Spine Plug & Play 125A – installation and maintenance
Installation and connection work is carried out by a qualified electrician. The equipment must be made dead before connection work, and the absence of voltage verified by measurement.
Place the equipment on level ground and so that it can be reached freely even when the site fills up with material. Material stacked in front blocks both use and emergency isolation.
Test the RCD with its test button at commissioning and at regular intervals afterwards. The test takes a second and is still almost always forgotten.
The unit weighs 4 kg. Take the weight into account when moving and lifting – damage is most often caused during transport, not in use.
Check the joints and fixings regularly during use. A joint that heats up is a sign of a fault and should be corrected before the fault spreads.
Spine Plug & Play 125A – safety and inspections
Site electrical installations are subject to the same requirements as fixed installations, and some of them are stricter. The equipment has to withstand moving, dust, moisture and mechanical stress for the whole project.
The installation is inspected at commissioning and regularly during use: enclosure, joints, the operation of the protective devices and the fact that live parts cannot be reached.
Damaged equipment is not repaired improvised on site. A cracked enclosure, a burnt terminal or a damaged socket is replaced – on a site a temporary repair almost always becomes permanent.
Document the configuration and any changes made. Up-to-date information on outputs and protection speeds up fault-finding and the next inspection.
Spine Plug & Play 125A – delivery and sizing help
We deliver the equipment together with the cables and the rest of the site power supply in one delivery, so the set is complete when it arrives on site.
Describe the whole site in your request for quotation: supply power, the outputs needed and the estimated length of the project. We size the set on that basis.
Use the product number 501310007 when ordering and when asking about spare parts. It identifies this exact model, which matters when the same series comes in several sizes.
We also help with the sizing. If you are unsure about the size or the number of outputs, ask us – equipment sized wrong costs more than equipment chosen right the first time.
Frequently asked questions
Does the unit need a fixed installation?
No. The unit plugs in between the board and the supply cable, so no electrician or fixed installation is needed.
How is Spine Plug & Play 125A set up?
Setup is done with the QR code on the enclosure, after which the unit automatically places itself in the correct spot on the Spine cloud service’s riser diagram.
What does the unit measure?
It measures power consumption, CO₂ emissions, per-phase load and voltage drop, among other things, and sends proactive alarms on deviations.
Can I name the unit myself in the cloud service?
Yes. The unit can be given any name or ID number in the Spine cloud service.
What is the product’s part number?
The part number is 501310007. You can use it for orders and quote requests.
Didn’t find the answer to your question? Add the product to the quote cart and our sales team will help — or open the chat in the bottom-right corner of the page.
What is the rated current of Spine Plug & Play 125A?
The rated current is 125 A.
What are the dimensions?
Dimensions: 25,5 x 18 x 11 cm.
How much does the product weigh?
Weight: 4 kg.
Do several measuring points appear in one view?
Yes. The same cloud service gathers all Spine units on the site into one view.
What is the product number?
The product number is 501310007. Use it in requests for quotation and spare part enquiries.
Request a quote for Spine Plug & Play 125A
Need a different current rating? See also the 16A model and the 32A model, or explore other solutions among our Spine products.
Once you’ve found the right model, add it to the quote cart. You can collect several products in the cart and send the whole list in one request.
The requirements for electrical installations on worksites are explained in more detail on the Tukes website.
Request a quotation
Add to the quotation basket and send us your request – we will confirm availability and delivery time. You can see the full range in the product group.