Subcabinet with phase measurement TSR IMKK-HUB 32A/VM

Product code (SKU): 5000332/32/VM

Subcabinet with phase measurement TSR IMKK-HUB 32A/VM

Subcabinet with meters that monitor the load of each of the three phases. A phase meter measures current and voltage. In addition, the meter acts as an indicator light to indicate that power is being applied to the phase.

Thanks to the phase-by-phase measurement, the even distribution of the load between the phases can be monitored on site, avoiding skewed loads and thereby preventing unnecessary gear overloads and fuse tripping.

The narrow shape of the center is designed so that the center takes up as little space as possible in the corridors of the construction site. The center is made of galvanized steel and has a light structure. The center is easy to hang on the wall from the hanging loops.

The center is manufactured in Finland and uses only high-quality European components such as PCE and Schneider. All parts of the center are available as spare parts. Changes can also be made to the center according to the customer’s wishes, e.g. the number and size of outlets can be modified.

SKU: 5000332/32/VM Categories: ,
Download product sheet (PDF)

Subcabinet with phase measurement TSR IMKK-HUB 32A/VM

Subcabinet with phase measurement TSR IMKK-HUB 32A/VM on the worksite

The distribution board is the site’s outlet point: power for hand tools, lighting and dryers is taken from it. It is placed close to the work so that extension cords stay short.

Boards are added as the site grows. The whole is worth planning in advance so that the supply is sufficient for all of them.

This model is rated 32 A. Size the equipment by the actual simultaneous load – the sum of the nameplate ratings almost always leads to oversizing.

Outputs: 1×32A(K), 2×16A, 6×16A/230V. Count the work points before choosing – the number of outputs decides how many machines one board can feed.

Where Subcabinet with phase measurement TSR IMKK-HUB 32A/VM is used

Typical sites are construction projects, renovations, industrial maintenance and event power. What they share is that the electrical supply is temporary and the conditions are demanding.

Temporary does not mean lighter requirements. Site equipment is exposed to dust, moisture, moving and mechanical stress in a way that fixed installations never are.

Check the load distribution between phases during use. Uneven distribution overloads one phase while the others run half empty, and the usual symptom is a fuse that keeps tripping.

Subcabinet with phase measurement TSR IMKK-HUB 32A/VM – how to choose the right model

The equipment is chosen by rated current and outputs. Start by calculating the simultaneous load and the output types needed, and choose the model on that basis.

Other models of the same type are Temporary power supply subcabinet 250 A, Sub cabinet 160 A, Sub cabinet TAK 125A KS, Sub cabinet TAK 63 A KS, Subcabinet TAK 32A.

Other details that affect the choice: protection class IP44, RCD 40A/30mA, weight 13,4 kg, dimensions 95×30×22 cm. These are worth checking already at the quotation stage.

You can see the full range in the product group, and read about real-time monitoring on the Spine page.

Subcabinet with phase measurement TSR IMKK-HUB 32A/VM – practical notes for use

Winter brings requirements of its own. Condensation forms when cold equipment is brought into the warm, and moisture inside the enclosure is a common reason for an RCD tripping with no visible cause.

Mark the equipment with the site details and keep a record of what is fed from where. On a site with several contractors that saves time at every fault-finding.

RCD protection is mandatory for socket outputs on a site. Its operation is tested with the test button at commissioning and at regular intervals afterwards.

Subcabinet with phase measurement TSR IMKK-HUB 32A/VM – installation and maintenance

Installation and connection work is carried out by a qualified electrician. The equipment must be made dead before connection work, and the absence of voltage verified by measurement.

Place the equipment on level ground and so that it can be reached freely even when the site fills up with material. Material stacked in front blocks both use and emergency isolation.

Test the RCD with its test button at commissioning and at regular intervals afterwards. The test takes a second and is still almost always forgotten.

The unit weighs 13,4 kg. Take the weight into account when moving and lifting – damage is most often caused during transport, not in use.

Check the joints and fixings regularly during use. A joint that heats up is a sign of a fault and should be corrected before the fault spreads.

Safety and inspections

Site electrical installations are subject to the same requirements as fixed installations, and some of them are stricter. The equipment has to withstand moving, dust, moisture and mechanical stress for the whole project.

The installation is inspected at commissioning and regularly during use: enclosure, joints, the operation of the protective devices and the fact that live parts cannot be reached.

Damaged equipment is not repaired improvised on site. A cracked enclosure, a burnt terminal or a damaged socket is replaced – on a site a temporary repair almost always becomes permanent.

Document the configuration and any changes made. Up-to-date information on outputs and protection speeds up fault-finding and the next inspection.

Delivery and sizing help

We deliver the equipment together with the cables and the rest of the site power supply in one delivery, so the set is complete when it arrives on site.

Describe the whole site in your request for quotation: supply power, the outputs needed and the estimated length of the project. We size the set on that basis.

Use the product number 5000332/32/VM when ordering and when asking about spare parts. It identifies this exact model, which matters when the same series comes in several sizes.

We also help with the sizing. If you are unsure about the size or the number of outputs, ask us – equipment sized wrong costs more than equipment chosen right the first time.

Frequently asked questions

What is the rated current of Subcabinet with phase measurement TSR IMKK-HUB 32A/VM?

The rated current is 32 A.

What outputs does the product have?

Outputs: 1×32A(K), 2×16A, 6×16A/230V.

Does the product have an RCD?

Residual current device (RCD): 40A/30mA.

What is the protection class?

Protection class: IP44.

What are the dimensions?

Dimensions: 95×30×22 cm.

How much does the product weigh?

Weight: 13,4 kg.

What is the product number?

The product number is 5000332/32/VM. Use it in requests for quotation and spare part enquiries.

Who may install the product?

Installation is carried out by a qualified electrician. The requirements are explained in more detail on the Tukes website.

Request a quotation

Add to the quotation basket and send us your request – we will confirm availability and delivery time. You can see the full range in the product group.

Technical information

Nominal Current

32 A

Nominal voltage

400 V

RCD

40A 30mA

Weight

13,4 kg

Dimensions (H x W x D)

95 x 30 x 22 cm

Lähdöt, (K ketjutukseen)

1 x 32A (K), 2 x 16A, 6 x 16A/230V

Fuses

2 x C16 3P
3 x C16 1P

Enclosure class

IP44