EZG 100/4 II/TN-S PTO generator 100 kVA / 80 kW for 200 hp tractors
Product code (SKU): E511507EZG 100/4 II/TN-S PTO generator 100 kVA / 80 kW for 200 hp tractors
Outlets: 3 x 230 V/16 A, 1 x CEE 400 V/16 A, 1 x CEE 400 V/32 A, 1 x CEE 400 V/125 A, 1 x CEE 400 V/125 A 1 h.
Endress EZG 100/4 II/TN-S is a tractor-driven PTO generator with a continuous output of 100 kVA / 80 kW. It has a switchable IT/TN network with insulation monitoring and suits tractors of about 200 hp.
EZG 100/4 II/TN-S is a PTO generator driven by the tractor’s power take-off. Its continuous output is 100 kVA / 80 kW. It is designed for agriculture, industry and standby power.

Add the product to the quotation basket and send your request – we confirm availability and delivery time at the same time.
EZG 100/4 II/TN-S – features
- Continuous output 100 kVA / 80 kW
- 400/230 V, 50 Hz, rated current 144.3 A, AVR voltage regulator
- Recommended tractor output approx. 200 hp
- Switchable IT/TN network, insulation monitoring in field use
- Automatic safety shutdown and all-pole miniature circuit breaker
- Indicator lights for setting the PTO speed, frequency and voltage display, operating hours counter
- Sockets: 3 x 230 V/16 A, 1 x CEE 400 V/16 A, 1 x CEE 400 V/32 A, 1 x CEE 400 V/125 A, 1 x CEE 400 V/125 A (1 h)
- Category 3 three-point linkage, steel frame with forklift pockets
- Generator IP rating IP44/54, weight approx. 560 kg
- Developed and manufactured in Germany
How a PTO generator works
The generator is driven by the tractor’s power take-off shaft, so no separate engine is needed. The rated PTO shaft speed is stated as 750 r/min.
Frequency and voltage depend on the rotation speed. For this reason, large indicator lights show the driver whether the speed is in the right range. This is the so-called traffic-light function.
In addition, the frequency and voltage display lets you follow use and load closely. The operating hours counter makes it easier to track servicing.
EZG 100/4 II/TN-S in field use and as standby power
In field use, the generator operates as an IT network with active insulation monitoring. The monitoring detects insulation faults and improves electrical safety in mobile installations.
When feeding a building’s electrical installation, the TN network is used. Protection is then provided by an all-pole miniature circuit breaker.
As a result, the same unit works both as a mobile power source and as standby power.
Sizing and choosing the tractor
The recommended tractor output is about 200 hp, and the rated current is 144.3 A.
The feed-in socket (5-pin CEE, 1 h) is designed for the generator’s maximum output. Two 125 A CEE outlets allow large loads and distribution boards to be fed.
This is the largest model in the series. If 80 kVA is enough, the EZG 80/4 II/TN-S needs a tractor of about 160 hp.
Mounting, transport and accessories
The generator attaches to the tractor’s category 3 three-point linkage. The sturdy steel frame has forklift pockets for moving it.
The weight is about 560 kg. The dimensions are 1130 x 740 x 1007 mm (L x W x H).
Accessories available: wheel kit E161036 and adapter for category 2 E162034. The feed-in socket CEE 400 V/125 A 1 h E135848 is also available.
EZG 100/4 II/TN-S in farm electrification
A PTO generator suits farms, livestock farms, machine halls, worksites and support for service vehicles. You can find all models in our generator range.
If no tractor is available, the same range also includes diesel generators with their own engine.
Safety
The automatic safety shutdown of the EZG 100/4 II/TN-S protects the electrical system from overload. The generator complies with the regulations and safety requirements for agriculture.
Keep the PTO shaft guards in place and stay clear of the rotating shaft. Moreover, place the tractor outdoors so exhaust gases cannot enter buildings.
Connection to a building’s installation is always made by a qualified electrician. The requirements for electrical work are explained on the Tukes website.
EZG 100/4 II/TN-S – technical data
| Continuous output | 100 kVA / 80 kW |
| Rated voltage | 400/230 V, 50 Hz |
| Rated current | 144.3 A |
| Voltage regulator | AVR |
| Generator IP rating | IP44/54 |
| Recommended tractor output | approx. 200 hp |
| Rated PTO shaft speed | 750 r/min |
| Three-point linkage | Category 3 |
| Network type | Switchable IT/TN |
| Sockets | 3 x 230 V/16 A, 1 x CEE 400 V/16 A, 1 x CEE 400 V/32 A, 1 x CEE 400 V/125 A, 1 x CEE 400 V/125 A (1 h) |
| Dimensions (L x W x H) | 1130 x 740 x 1007 mm |
| Weight | approx. 560 kg |
| Country of manufacture | Germany |
| Product number | E511507 |
Frequently asked questions
What size of tractor does the EZG 100/4 II/TN-S need?
The recommended tractor output is about 200 hp.
Can the generator feed a building’s electrical installation?
Yes, in TN network mode. The connection is made by a qualified electrician, and protection is provided by an all-pole miniature circuit breaker.
Which accessories are available?
Wheel kit E161036 and adapter for category 2 E162034. The feed-in socket CEE 400 V/125 A 1 h E135848 is also available.
What is the product number?
The product number (MPN) is E511507. Use it in quotation requests.
Request a quote
Add the product to the quotation basket and send your request. Tell us your tractor output, linkage category and what you plan to power. We can combine the generator and accessories in the same quote.