Sub distribution board 125A with Spine monitoring HUB 125/VM
Product code (SKU): 505010008Sub distribution board 125A with Spine monitoring HUB 125/VM
Sub Distribution Board with Phase Meters and Spine Remote Monitoring
This sub distribution board is built for demanding construction site conditions where reliable power distribution, balanced phase loads, and remote monitoring are essential. The unit is equipped with the Spine remote monitoring system, which enables real-time tracking of energy consumption, setting predictive alerts, and monitoring power conditions remotely. The system is easy to activate via QR code.
The board features VM phase meters that measure the voltage and current of each of the three phases individually. These meters also function as indicator lights, showing whether power is present on each phase. Step-by-step phase monitoring helps ensure balanced load distribution, reducing the risk of phase imbalance and unnecessary fuse tripping.
The stackable design keeps the outlets and socket boxes protected inside the frame. The sub distribution board is manufactured in Finland from durable galvanized steel and built with premium European components, such as PCE and Schneider. All parts are available as spare parts. The unit is also fully customizable based on customer and county’s needs—for example, the number and type of outlets and fuses can be modified.
Sub distribution board 125A with Spine monitoring HUB 125/VM
This worksite board is designed for demanding conditions where power distribution management, load monitoring and real-time remote monitoring play a central role. The board comes with the Spine remote monitoring system as standard, letting you measure energy consumption, set up proactive alarms and monitor the electrical network’s status remotely. Setup is quick with a QR code.
The board also has VM phase meters, which measure each phase’s current and voltage separately. The meters double as indicator lights that show current arriving at each phase. Per-phase measurement makes it possible to distribute the load evenly, which prevents unbalanced load and reduces unnecessary fuse trips.
The stackable design protects the outlets and outputs inside the frame. The board is made of strong, galvanized steel and manufactured in Finland. Only high-quality European components are used, such as PCE and Schneider. All parts are available as spare parts, and the board’s configuration can be tailored to the customer’s needs — for example, the number and size of the outlets can be changed.

Sub distribution board 125A with Spine monitoring HUB 125/VM – technical data
- Rated current: 125 A
- Rated voltage: 400 V
- RCD: 4 x 300mA, 2 x 30 mA
- Socket outlets: 12 x 16A/230V, 2 x 16A, 4 x 32 A, 2 x 63 A
- Dimensions (W x D x H): 80 x 30 x 83cm
- Enclosure rating: IP44
- Weight: 41 kg
- Model: HUB 125/VM
- Approvals: CE
Does this model suit your site? Add the product to the quote cart at the top of the page to get a quote.
Sub distribution board 125A with Spine monitoring HUB 125/VM on the worksite
Spine is a remote monitoring system. Measurement data is sent to the cloud service where it can be viewed on any device – nobody needs to travel to the site to read a meter.
The service shows electricity consumption, load distribution between phases, voltage drop and CO₂ emissions, among others. Predictive alarms can be set so a deviation is caught before it stops the work.
The same cloud service gathers every Spine unit on the site into one view, however many measuring points there are.
This model is rated 125 A. Size the equipment by the actual simultaneous load – the sum of the nameplate ratings almost always leads to oversizing.
Outputs: 12 x 16A/230V, 2 x 16A, 4 x 32 A, 2 x 63 A. Count the work points before choosing – the number of outputs decides how many machines one board can feed.
Where Sub distribution board 125A with Spine monitoring HUB 125/VM is used
Typical sites are construction projects, renovations, industrial maintenance and event power. What they share is that the electrical supply is temporary and the conditions are demanding.
Temporary does not mean lighter requirements. Site equipment is exposed to dust, moisture, moving and mechanical stress in a way that fixed installations never are.
Check the load distribution between phases during use. Uneven distribution overloads one phase while the others run half empty, and the usual symptom is a fuse that keeps tripping.
Sub distribution board 125A with Spine monitoring HUB 125/VM – how to choose the right model
The equipment is chosen by rated current and outputs. Start by calculating the simultaneous load and the output types needed, and choose the model on that basis.
Other models of the same type are Spine Plug & Play 16A, Spine Plug & Play 32A, Spine Plug & Play 63A, Spine Plug & Play 125A, Spine for 16A-1250A centers with fixed input.
Other details that affect the choice: protection class IP44, RCD 4 x 300mA, 2 x 30 mA, weight 41 kg, dimensions 80 x 30 x 83cm. These are worth checking already at the quotation stage.
You can see the full range in the product group, and read about real-time monitoring on the Spine page.
Sub distribution board 125A with Spine monitoring HUB 125/VM – practical notes for use
Winter brings requirements of its own. Condensation forms when cold equipment is brought into the warm, and moisture inside the enclosure is a common reason for an RCD tripping with no visible cause.
Mark the equipment with the site details and keep a record of what is fed from where. On a site with several contractors that saves time at every fault-finding.
RCD protection is mandatory for socket outputs on a site. Its operation is tested with the test button at commissioning and at regular intervals afterwards.
Sub distribution board 125A with Spine monitoring HUB 125/VM – installation and maintenance
Installation and connection work is carried out by a qualified electrician. The equipment must be made dead before connection work, and the absence of voltage verified by measurement.
Place the equipment on level ground and so that it can be reached freely even when the site fills up with material. Material stacked in front blocks both use and emergency isolation.
Test the RCD with its test button at commissioning and at regular intervals afterwards. The test takes a second and is still almost always forgotten.
The unit weighs 41 kg. Take the weight into account when moving and lifting – damage is most often caused during transport, not in use.
Check the joints and fixings regularly during use. A joint that heats up is a sign of a fault and should be corrected before the fault spreads.
Safety and inspections
Site electrical installations are subject to the same requirements as fixed installations, and some of them are stricter. The equipment has to withstand moving, dust, moisture and mechanical stress for the whole project.
The installation is inspected at commissioning and regularly during use: enclosure, joints, the operation of the protective devices and the fact that live parts cannot be reached.
Damaged equipment is not repaired improvised on site. A cracked enclosure, a burnt terminal or a damaged socket is replaced – on a site a temporary repair almost always becomes permanent.
Document the configuration and any changes made. Up-to-date information on outputs and protection speeds up fault-finding and the next inspection.
Delivery and sizing help
We deliver the equipment together with the cables and the rest of the site power supply in one delivery, so the set is complete when it arrives on site.
Describe the whole site in your request for quotation: supply power, the outputs needed and the estimated length of the project. We size the set on that basis.
Use the product number 505010008 when ordering and when asking about spare parts. It identifies this exact model, which matters when the same series comes in several sizes.
We also help with the sizing. If you are unsure about the size or the number of outputs, ask us – equipment sized wrong costs more than equipment chosen right the first time.
Frequently asked questions
How do the VM phase meters help prevent unbalanced load?
The phase meters measure each phase’s current and voltage separately and double as indicator lights. This makes it easy to distribute the load evenly across the phases, which prevents unbalanced load and unnecessary fuse trips.
Can the board’s configuration be customized?
Yes. The number and size of outlets and boxes can be customized to the customer’s needs, and all parts are available as spare parts.
Does the board include Spine remote monitoring?
Yes, as standard. The Spine system lets you measure energy consumption, set up proactive alarms and monitor the electrical network’s status remotely. Setup is done with a QR code.
What is the product’s part number?
The part number is 505010008. You can use it for orders and quote requests.
Didn’t find the answer to your question? Add the product to the quote cart and our sales team will help — or open the chat in the bottom-right corner of the page.
What is the rated current of Sub distribution board 125A with Spine monitoring HUB 125/VM?
The rated current is 125 A.
What outputs does the product have?
Outputs: 12 x 16A/230V, 2 x 16A, 4 x 32 A, 2 x 63 A.
Does the product have an RCD?
Residual current device (RCD): 4 x 300mA, 2 x 30 mA.
What is the protection class?
Protection class: IP44.
What are the dimensions?
Dimensions: 80 x 30 x 83cm.
How much does the product weigh?
Weight: 41 kg.
Do several measuring points appear in one view?
Yes. The same cloud service gathers all Spine units on the site into one view.
What is the product number?
The product number is 505010008. Use it in requests for quotation and spare part enquiries.
Who may install the product?
Installation is carried out by a qualified electrician. The requirements are explained in more detail on the Tukes website.
Request a quote for Sub distribution board 125A with Spine monitoring HUB 125/VM
Explore other sub centers and Spine products.
Once you’ve found the right model, add it to the quote cart. You can collect several products in the cart and send the whole list in one request.
Request a quotation
Add to the quotation basket and send us your request – we will confirm availability and delivery time. You can see the full range in the product group.
Technical information
| Nominal Current | 125 A |
|---|---|
| Nominal voltage | 400 V |
| RCD | 4 x 300mA, 2 x 30 mA |
| Sockets | 12 x 16A/230V, 2 x 16A, 4 x 32 A, 2 x 63 A |
| Dimensions (W x D x H) | 80 x 30 x 83cm |
| Enclosure class | IP44 |
| Weight | 41 kg |
| Model | HUB 125/VM |
| Approvals | CE |