SPINE · ELECTRICITY

Power consumption and network health in real time.

Spine electricity continuously measures each phase’s load, voltage and power. You see where the power goes, which device is consuming it and where the network is unevenly loaded, and you get an alarm before a fuse blows. Spine electricity brings the whole network into one view.

TSR-HUB 63 · Site 4, Turku● Live
Total consumption since project start
12,677 kWh
Phase L1
52 A
Phase L2
27 A
Phase L3
22 A
Total power
21.4 kW
Phases unbalanced: L1 load is too high, risk of fuse trip
Included with every Spine device Automatic 4G, no local network needed Continuous monitoring and proactive alarms MID-approved metering available as an option
The situation without Spine

Unbalanced load only shows up once the fuse trips

One phase carries most of the board’s load while another sits nearly empty. No one sees it on site until the overloaded phase trips the fuse mid-shift and the whole board goes dark.

Loads

Per-phase load stays a guess until someone visits the site with a meter.

Fuses

An overload always trips the fuse at the worst time, usually mid-way through the most critical task.

Reporting

Consumption ends up as a single number for the whole site, even though the bill should be split by contractor.

Responsibility

When the board goes dark, time first goes into finding the fault and only then fixing it.

What Spine measures

Spine electricity: four measurements that reveal the network’s condition

All measurement happens at the board the power flows through — no separate clamp meters or site visits needed.

  • Voltage Electrical equipment needs a stable, correctly sized voltage. Spine detects unusual over- or undervoltage and raises the alarm before sensitive equipment is damaged.
  • Current An overloaded network leads to a tripped fuse and an outage. Spine shows you the per-phase load and lets you set an alarm threshold that warns proactively.
  • Per-phase load An unevenly loaded network burns out on one phase, even when the total load looks moderate. Spine reveals the imbalance immediately.
  • Power and consumption When a single device or machine is connected to the board, you see exactly how much it consumes — useful, for example, when choosing between an electric and a diesel heater.
Sub central FUC125X Spine for site cabins, with Spine real-time remote monitoring built in.
Reporting

Consumption, cost and emissions broken down by area

A report can be scoped to the whole site or part of it, for example just the site offices or a single contractor’s area.

Energy report

Energy consumption and alarms for a chosen period, for the whole site or part of it. Ready to attach to documentation.

Cost and spot price

The electricity price can be set as fixed or tracking the spot price, so the cost shown is actual, not an estimate.

CO₂ emissions

Emissions are calculated from consumption, so the figure is ready whenever a client or an environmental certification asks for it.

Alarms and control

What Spine electricity alerts you to, and what it handles itself

Alarms arrive by text message and email. Thresholds are configured in the app to match the site.

OverloadPhase approaching rated current
Over- and undervoltageSensitive equipment at risk
Phase imbalanceRisk of a blown fuse
Power outageSupply cut from the board
Connection lostDevice no longer reporting
Rising temperatureHeat inside the board

Beyond measuring, Spine also controls: devices and lighting can be switched on and off remotely or on a schedule. See Control.

Products

Spine electricity: products for power distribution

Spine is available integrated into a board or as a separate Plug & Play device. Add a product to the quote cart, and we’ll get in touch with a quote for your site.

Sub distribution board with Spine TSR HUB 32A

Sub distribution board with Spine TSR HUB 32A

505010006
Rated current: 32 A
Outputs: 2 × 32 A, 2 × 16 A, 6 × 16 A 230 V
Enclosure rating: IP44
Sub distribution board with Spine TSR HUB 63A

Sub distribution board with Spine TSR HUB 63A

505010007
Rated current: 63 A
Outputs: 1 × 63 A, 2 × 32 A, 2 × 16 A, 6 × 16 A 230 V
Enclosure rating: IP44
Sub distribution board 125A with Spine monitoring HUB 125/VM

Sub distribution board 125A with Spine monitoring HUB 125/VM

505010008
Rated current: 125 A
Socket outlets: 12 × 16 A/230 V, 2 × 16 A, 4 × 32 A, 2 × 63 A
Weight: 41 kg
Subcabinet with fixed input TSR 63/125A Spine

Subcabinet with fixed input TSR 63/125A Spine

505010009
Rated current: 63 A
Outputs: 1 × 63 A, 2 × 32 A, 1 × 16 A, 6 × 16 A 230 V
Enclosure rating: IP44
Sub center 32A TSR-UC32 with Spine

Sub center 32A TSR-UC32 with Spine

505010010
Rated current: 32 A
Socket outlets: 1 × 32 A, 3 × 16 A, 6 × 16 A/230 V
Weight: 16.95 kg
Sub central with fixed incoming FUC125 Spine

Sub central with fixed incoming FUC125 Spine

505010005
Rated current: 125 A
Socket outlets: 2 × 63 A, 2 × 32 A, 1 × 16 A, 3 × 230 V/16 A
Enclosure rating: IP44
Spine for 16A-1250A centers with fixed input

Spine for 16A-1250A centers with fixed input

501310006
Rated current: 16–1250 A
Rated voltage: 400 V
Weight: 2.5 kg
Spine Plug & Play 16A

Spine Plug & Play 16A

501310005
Rated current: 16 A
Rated voltage: 400 V
Weight: 1.8 kg
Spine Plug & Play 32A

Spine Plug & Play 32A

501310004
Rated current: 32 A
Rated voltage: 400 V
Weight: 2 kg
Spine Plug & Play 63A

Spine Plug & Play 63A

501310003
Rated current: 63 A
Rated voltage: 400 V
Weight: 3.2 kg
Spine Plug & Play 125A

Spine Plug & Play 125A

501310007
Rated current: 125 A
Rated voltage: 400 V
Weight: 4 kg

Spine electricity is also available integrated into modular boards and connection cabinets. Ask about a configuration for your site →

Documents

The device’s paperwork lives with the device

The Spine service stores each device’s inspection and test records, manuals and site drawings. They’re still there a year later, even if the folder is long gone and the installer has changed.

  • Inspection and test records Commissioning inspections and measurement reports are stored directly against the device.
  • Manuals and maintenance instructions The same instructions for everyone using the device on site, shift after shift.
  • Site drawings and riser diagrams A real-time riser diagram is generated automatically, and you can upload your own drawings alongside it.
  • The whole project’s history Data and documents are kept for the project’s entire lifecycle, even after the site is finished.
The Spine electricity app shows a site's devices and their measurement data on a phone.
Next step

Two ways to proceed

You already know what you need

Request a quote

You know the board requirement and the currents — add Spine electricity products to the quote cart, and we’ll put together a quote.

Go to products →
You’d rather talk it through first

Book a free 30-min consultation

We’ll go through the site’s electrification and metering needs and figure out what configuration fits.

Book a time →
Frequently asked questions

Answers about electricity metering

Is the energy metering MID-approved?

MID-approved energy metering is available as an optional add-on, for when consumption is used as the basis for billing. Read more about the EU Measuring Instruments Directive (MID).

Can Spine show a single device’s consumption?

Yes. When a single device or machine is connected to the board, its consumption can be read separately. This means, for example, comparing heating solutions is based on measured data.

Is the riser diagram generated automatically?

Yes. Spine builds the site’s electrical riser diagram in real time, and you can upload your own drawings, test reports and manuals alongside it.

Can consumption be allocated to contractors?

Yes. A report can be scoped to part of a site, for example one contractor’s area or the site offices, so the cost can be split according to actual consumption.