BET center 63A

Tuotetunnus (SKU): 5000310

BET center 63A

BET center is a switch board with 12pcs 230V shuko socket outlets. Each outlet has its own current and voltage meter and quick-release fuse. The green light on the meters acts as a distinguishable indicator from a distance that power is coming to that socket.

The BET center can be used as a power source for concrete heating cables, so by following the consumption figures reported by the meters, it is easy to ensure that each heating cable is working properly. The BET center is also great for e.g. as a center for pumps, heaters and lighting or a charging center for for hand tools’ batteries.

In addition to each socket’s own meter, the BET center has current and voltage meters that measure whole center’s three phases. The purpose of the phase meters is to keep the center’s load evenly distributed between all three phases. If the load of one phase is greater than the others, it is a skewed load, which should be quickly equalized.

In the BET center, each phase is also behind its own fault current protection.

L1 = left side
L2 = anterior
L3 = right side

The center is supplied with a 63A incoming plug. The sturdy BET center can be hung on the wall or stand on its own feet on the floor. The powder-coated center is made of aluminum.

Download product sheet (PDF)

BET center 63A – bET center is a switch board with 12pcs 230V shuko socket outlets. Each outlet has its own current and voltage meter and quick-release fuse. The green light on the meters acts as a distinguishable indicator from a distance that power is coming to that socket. The BET center can be used as a power source for concrete heating cables, so by following the consumption figures reported by the meters, it is easy to ensure that each heating cable is working properly. The BET center is also great for e.g. as a center for pumps, heaters and lighting or a charging center for for hand tools’ batteries. In addition to each socket’s own meter, the BET center has current and voltage meters that measure whole center’s three phases. The purpose of the phase meters is to keep the center’s load evenly distributed between all three phases. If the load of one phase is greater than the others, it is a skewed load, which should be quickly equalized. In the BET center, each phase is also behind its own fault current protection. L1 = left side L2 = anterior L3 = right side The center is supplied with a 63A incoming plug. The sturdy BET center can be hung on the wall or stand on its own feet on the floor. The powder-coated center is made of aluminum.

BET center 63A

BET center 63A on the worksite

The distribution board is the site’s outlet point: power for hand tools, lighting and dryers is taken from it. It is placed close to the work so that extension cords stay short.

Boards are added as the site grows. The whole is worth planning in advance so that the supply is sufficient for all of them.

This model is rated 63 A. Size the equipment by the actual simultaneous load – the sum of the nameplate ratings almost always leads to oversizing.

Outputs: 12 x schuko 230V. Count the work points before choosing – the number of outputs decides how many machines one board can feed.

Where BET center 63A is used

Typical sites are construction projects, renovations, industrial maintenance and event power. What they share is that the electrical supply is temporary and the conditions are demanding.

Temporary does not mean lighter requirements. Site equipment is exposed to dust, moisture, moving and mechanical stress in a way that fixed installations never are.

Check the load distribution between phases during use. Uneven distribution overloads one phase while the others run half empty, and the usual symptom is a fuse that keeps tripping.

How to choose the right model

The equipment is chosen by rated current and outputs. Start by calculating the simultaneous load and the output types needed, and choose the model on that basis.

Other models of the same type are Temporary power supply subcabinet 250 A, Sub cabinet 160 A, Sub cabinet TAK 125A KS, Sub cabinet TAK 63 A KS, Subcabinet TAK 32A.

Other details that affect the choice: RCD 3 x 30 mA, dimensions 49×33×56 cm. These are worth checking already at the quotation stage.

You can see the full range in the product group, and read about real-time monitoring on the Spine page.

Practical notes for use

Winter brings requirements of its own. Condensation forms when cold equipment is brought into the warm, and moisture inside the enclosure is a common reason for an RCD tripping with no visible cause.

Mark the equipment with the site details and keep a record of what is fed from where. On a site with several contractors that saves time at every fault-finding.

RCD protection is mandatory for socket outputs on a site. Its operation is tested with the test button at commissioning and at regular intervals afterwards.

BET center 63A – installation and maintenance

Installation and connection work is carried out by a qualified electrician. The equipment must be made dead before connection work, and the absence of voltage verified by measurement.

Place the equipment on level ground and so that it can be reached freely even when the site fills up with material. Material stacked in front blocks both use and emergency isolation.

Test the RCD with its test button at commissioning and at regular intervals afterwards. The test takes a second and is still almost always forgotten.

Check the joints and fixings regularly during use. A joint that heats up is a sign of a fault and should be corrected before the fault spreads.

Safety and inspections

Site electrical installations are subject to the same requirements as fixed installations, and some of them are stricter. The equipment has to withstand moving, dust, moisture and mechanical stress for the whole project.

The installation is inspected at commissioning and regularly during use: enclosure, joints, the operation of the protective devices and the fact that live parts cannot be reached.

Damaged equipment is not repaired improvised on site. A cracked enclosure, a burnt terminal or a damaged socket is replaced – on a site a temporary repair almost always becomes permanent.

Document the configuration and any changes made. Up-to-date information on outputs and protection speeds up fault-finding and the next inspection.

Delivery and sizing help

We deliver the equipment together with the cables and the rest of the site power supply in one delivery, so the set is complete when it arrives on site.

Describe the whole site in your request for quotation: supply power, the outputs needed and the estimated length of the project. We size the set on that basis.

Use the product number 5000310 when ordering and when asking about spare parts. It identifies this exact model, which matters when the same series comes in several sizes.

We also help with the sizing. If you are unsure about the size or the number of outputs, ask us – equipment sized wrong costs more than equipment chosen right the first time.

BET center 63A – technical data

Rated current 63 A
Rated voltage 230 V
Outputs 12 x schuko 230V
Residual current device (RCD) 3 x 30 mA
Material Alumiini
Dimensions (W×D×H) 49×33×56 cm

Frequently asked questions

What is the rated current of BET center 63A?

The rated current is 63 A.

What outputs does the product have?

Outputs: 12 x schuko 230V.

Does the product have an RCD?

Residual current device (RCD): 3 x 30 mA.

What are the dimensions?

Dimensions: 49×33×56 cm.

What is the product number?

The product number is 5000310. Use it in requests for quotation and spare part enquiries.

Who may install the product?

Installation is carried out by a qualified electrician. The requirements are explained in more detail on the Tukes website.

The requirements for electrical installations on worksites are explained in more detail on the Tukes website.

Request a quotation

Add to the quotation basket and send us your request – we will confirm availability and delivery time at the same time. You can see the full range in the product group.

Tekniset tiedot

Dimensions 33 × 49 × 56 cm
Nominal Current

63A

Nominal voltage

230V

RCD

3 x 30mA

Dimensions (W x D x H)

49 x 33 x 56 cm

Outlets

12 x shuko 230V

Material

Aluminium