Site heating

Modular hybrid heating

Modular hybrid heating with Aurora Block gives construction sites, properties and industry heating, cooling and drying from the same modules. Start with one module and add capacity as the need grows. Spine runs the whole system automatically and can be operated remotely.

Go straight to the product details →
Example view: a six-storey site · the values are illustrativeExample
Heat demand
155.2 kW
Modules running
5 / 5
Outdoor temperature
−26.7 °C
Flow / return
+64 / +27 °C
The heat pumps carry the base load. Aurora 64 has started to supply additional output because the outdoor temperature has dropped below the design temperature.
In every configuration From a single 28 kW module Heating, cooling and drying from the same equipment Spine remote control, five-year licence HVO-compatible backup
The situation without Aurora Block

Heating is sized once — and paid for all winter

Temporary heating is often handled with a single large unit that has to fit on the plot and that runs at the same output whatever the conditions. Modular hybrid heating starts from the other end: capacity is added as the need grows.

Space

The heating container does not fit on the plot

A tight city-centre site has neither room for a large container nor a route to move it. Stackable modules fit into narrow installation corridors and can be lifted onto an intermediate floor or a roof.

Sizing

Capacity is oversized just in case

When output cannot be added later, it is bought up front for the coldest spell. For most of the winter the equipment then runs at part load.

Cost

Oil is burned even when it is not needed

In a single-source system the fuel is consumed the same way at zero degrees as in hard frost. A heat pump would produce the same heat at a fraction of the cost.

Risk

An interruption stops the drying

A power cut or a fault stops the heating, and the structures stop drying. The schedule slips even if the fault itself is fixed quickly.

The system

How modular hybrid heating works — one water circuit, three heat sources

The modules are connected in series in the same water circuit. Water returning from the site runs through the chain, every module in operation adds heat, and the last one feeds the building.

SPINE — ONE CONTROL LAYERcascade control · remote access · alarms · energy consumption · Spine Valve
AURORA 28
air-to-water
AURORA 50
ground source
AURORA 64
oil boiler
+ N MODULES
no upper limit
FLOW
BUILDING / SITE
  • Heating network
  • WH water circuit heaters
  • Floor heating and drying
direct connection · separate circuits · open spaces
RETURN — cold water enters the first module · every module adds heat · the last one feeds the building
▫ = shut-off valve · at both ends of every module — isolate, service or swap a module mid-chain

1.Water runs through the modules. Return water from the site is led into the Aurora chain. The modules are connected in series in the same water circuit.

2.Spine uses only the capacity needed. The heat pumps run first, the electric element as backup and oil heating last.

3.Heat is transferred to the site. Aurora can be connected straight to the heating network or to water circuit heaters.

4.Capacity can be added. As the demand grows, more modules are connected to the same circuit with no upper limit.

Calculate the heating energy your site needs

Arctic Warm’s free calculator gives you the output demand and a suitable module combination before you request a quote.

Open the calculator →
Control

Spine runs the whole system

Spine remote control is included with every module as standard, together with a five-year licence. The same platform also monitors site electricity and conditions.

Output control

Automatic cascade control

Spine starts only as many modules as the demand requires. The heat pumps act as the primary heat source, the electric element as backup and oil last.

Remote access

Remote control and alarms

You see temperatures, energy consumption and equipment status remotely. Settings can be changed without a site visit, and deviations raise automatic alarms.

One platform

The same system for heat and power

Spine can also monitor site power distribution. Spine Valve lets you control heating floor by floor or zone by zone on the same platform.

Applications

Where modular hybrid heating fits

Temporary heating

Replaces heat production while a boiler, a district heating substation or another system is out of service.

Site heating and drying

Produce the heat for water circuit heaters and adjust the conditions to the work stage.

Long-running sites

Aurora 50 uses ground-source energy and suits installations that last for months or years.

Backup output

Aurora 64 adds output to the system and keeps the heating running through a power cut.

Modular hybrid heating with Aurora Block warming a hall on a construction site
The same equipment heats the hall, dries the structures and cools in summer.
Sizing

Sizing modular hybrid heating: example configurations

Modular hybrid heating is sized in modules: build the capacity you need one module at a time. Air-to-water heat pumps, ground-source heat pumps and the oil backup can be combined in the same set-up.

ConfigurationOutputOutput at −15 °CTypical site
1 × Aurora 2828 kW23 kWSite huts, small buildings, drying
2 × Aurora 2856 kW46 kWTemporary heating for an apartment building
4 × Aurora 28 + Aurora 64176 kW156 kW · 80 kW of coolingHeat pumps for the base load, oil for peak and backup
2 × Aurora 50 + Aurora 64167 kW144 kW from the ground-source modules + 64 kW oil backupLong-running temporary installations
8 × Aurora 28 + 3 × Aurora 64416 kW375 kW · 160 kW of coolingCampuses, industrial halls, large properties

Peak outputs: Aurora 28 A7/W35, Aurora 50 B10/W35, Aurora 64 nominal. Outputs at −15 °C: Aurora 28 A−15/W35, Aurora 50 B0/W35. The 9 kW electric element in Aurora 28 is not included in the figures above.

Cooling

The same modular hybrid heating equipment also cools

Modular hybrid heating is not only about heat. Aurora 28 heats in winter and cools in summer: the modules are connected in series in exactly the same way, and Spine adjusts the cooling output to demand. Only the modules that are needed run — the rest stay on standby. One set of equipment, used all year.

Example view: an office floor in cooling mode · the values are illustrativeExample
Cooling demand
52.4 kW
Modules running
3 / 4
Outdoor temperature
+34.6 °C
Chilled flow / return
+7 / +12 °C
The fourth module stays on standby. Spine brings it online only if the cooling demand rises.
Aurora Block cooling a server room temporarily

Cooling where it is needed

Temporary cooling

Replaces a building’s own cooling during a fault, a service break or a renovation.

Server and electrical rooms

Temporary or seasonal cooling for IT and electrical spaces that cannot be allowed to overheat.

Events, halls and tents

Add or remove capacity according to the space and the situation, from a single module upwards.

Drying and humidity control

Combining cooling and heating removes moisture from the air and keeps site conditions under control.

Care and residential spaces

Temporary cooling during heatwaves for buildings with no adequate fixed cooling.

Process cooling

Temporary cooling capacity for industry without a permanent investment.

ConfigurationCooling outputTypical site
1 × Aurora 2820 kWServer room, small office, meeting room
2 × Aurora 2840 kWEvent tent, retail space, care home ward
4 × Aurora 2880 kWTemporary cooling for an office building during a fault or a renovation
8 × Aurora 28160 kWHalls, campuses, process cooling

Nominal cooling output 20 kW (A35). EER 3.55 at a flow temperature of +18 °C and 2.22 at +7 °C. The circulating fluid can be water, glycol or ethanol. Cooling is delivered by Aurora 28; Aurora 50 also cools, while Aurora 64 is a heat-only unit.

Technical

Modular hybrid heating — system basics

Connection
2″ flange
DN50 · PN16
Main line
50 mm
recommended · 32–63 mm possible
Circulating fluid
Water · glycol · ethanol
closed circuit · max. 3 bar
Construction
Acid-proof
pipework and frame · self-venting circulation pump
Weights
370–495 kg
Aurora 28: 370 kg · Aurora 50: 495 kg · Aurora 64: 450 kg
Spine
5 years
licence included with every module
Modules

Comparing the modules

Three modules in the same water circuit. Each of them also works on its own.

PropertyAurora 28Aurora 50Aurora 64
Unit typeAir-to-water heat pumpGround-source heat pumpCondensing oil boiler (diesel/HVO)
SKU105060100110506010041050601002
Output11.4–28 kW20–51 kW64 kW
COP / efficiencyup to 4.14.5 (B0/W35)90–98 %
Fluid temperature range−10…+60 °C−12…+60 °Cup to +90 °C
Main functionsHeating, cooling, dryingHeating, coolingBackup and peak heat
Role in the hybridBase loadBase load on ground-source sitesPeak output, backup and power cuts
CoolingYes, 20 kW (A35)YesNo
Power supply32 A / 400 V3 × 32 A / 400 V230 V · 8 h battery
Fuel tank––approx. 500 L (also HVO)
Dimensions (W × D × H)1140 × 1440 × 1600 mm
Weight370 kg495 kg450 kg
Connection2″ flange · DN50 · PN16
Spine remote controlStandard, five-year licence included
PlacementStackable and liftable modules
Ground thawing

Aurora Frost — ground thawing as a unit of its own

Ground thawing is not part of the modular hybrid heating water circuit; it has its own mobile trailer. The heat comes from the same 64-kilowatt condensing oil boiler as in the Aurora 64 module.

Aurora Frost ground thawing trailer on a winter construction site, motorised hose reels visible

0–400 m² thawing area

600 metres of thawing hose on motorised reels — one person can roll the hose out and reel it back in.

A standalone unit

Mobile trailer, 230 V supply, 700 kg with an empty tank. No other Aurora equipment is needed on site.

FAQ

Frequently asked questions about modular hybrid heating

What does modular hybrid heating mean?

The system is built from separate modules that are joined into the same water circuit to form one whole. It uses several heat sources – air, ground and fuel – and Spine switches between them automatically according to the conditions.

Where are the modules connected on site?

Aurora can be connected straight to the building’s heating network, to a separate circuit or to water circuit heaters. The connection is a 2-inch flange (DN50, PN16) and the recommended main line is 50 mm.

When does the backup heat start?

Automatically, when the heat pumps cannot cover the demand or the power fails. The Aurora 64 oil boiler has an eight-hour battery backup and produces water at up to +90 °C.

Can a single module be removed for service mid-season?

Yes. Every module has shut-off valves at both ends, so one module can be isolated, serviced or swapped mid-chain while the rest of the system keeps running.

How much cooling can the system deliver?

Aurora 28 provides a nominal 20 kW of cooling (A35), so four modules give 80 kW and eight give 160 kW. The EER is 3.55 at a +18 °C flow temperature and 2.22 at +7 °C.

Can the same modules heat and cool in the same season?

Yes. The equipment is switched between heating and cooling as the need changes, which makes it practical for sites that are dried in spring and cooled in summer.

How far does the system scale?

From one module upwards with no fixed ceiling. The example configurations reach 416 kilowatts, and capacity is added in stages as the build progresses.

Which circulating fluid does the system use?

Water, glycol or ethanol in a closed circuit at a maximum of 3 bar. The pipework and frame are acid-proof and the circulation pump is self-venting.

Where can the modules be placed?

The modules are stackable and fit into narrow installation corridors. They can also be lifted onto a balcony, an intermediate floor or a roof.

Is the system suitable for ground thawing?

Ground thawing uses a separate Aurora Frost trailer with 600 metres of thawing hose and a thawing area of 0–400 m². It is not part of the water circuit chain.

Does the site need a separate network connection?

No. Spine remote control is built into the modules and works without a local network.

Heat distribution

TSR WH water circuit heaters

Modular hybrid heating produces the heat, and the water circuit heaters distribute it around the space. Pick the output to match the size of the site.

Downloads

Aurora Block product sheets

Every unit has a one-page product sheet in PDF format. The sheet covers the key features, the Spine integration and the full technical table.

Next step

Two ways forward

You already know what you need

Request a quote

Add the modules you want to the quote cart and send the request. We will size a suitable configuration for your site and confirm the delivery time.

Go to the modules →
You are not sure of the sizing yet

Calculate the heating energy demand

Arctic Warm’s free calculator gives you the site’s output demand and a suitable module combination. A ready sizing speeds up the quote.

Open the calculator →

The rest of our site heating equipment is on the worksite heating page.