Aurora 64 oil boiler 64 kW – backup heating unit, 8 h battery backup

Product code (SKU): 1050601002

Aurora 64 oil boiler 64 kW – backup heating unit, 8 h battery backup

Aurora 64 oil boiler is the backup heating unit and redundancy layer of the Aurora Block system. It secures heat production during power outages, exceptional situations and extreme conditions.

  • 64 kW output, 90–98 % efficiency (condensing technology)
  • HVO-compatible fuel tank, approx. 500 L
  • Operates through power outages – 8 h battery backup
  • Minimal electrical demand: single-phase, max 500 W
  • Fluid heating up to 90 °C
  • Stainless steel piping and frame, dry weight 450 kg
  • 2″ flange connection, modules are stackable
  • Spine remote control as standard, 5-year licence included
SKU: 1050601002 Categories: ,
Download product sheet (PDF)

Aurora 64 oil boiler is the redundancy layer of the Aurora Block system – a reliable backup and peak power unit that secures heat production during power outages and extreme conditions. Output is 64 kW, efficiency 90–98 % and the flow temperature up to 90 °C. The unit has an HVO-compatible fuel tank of approximately 500 litres and eight hours of battery backup. The SKU is 1050601002.

Who is the Aurora 64 oil boiler for?

The unit is meant for sites where heat production must not stop. It complements heat pump–based modules whenever other energy sources are unavailable or capacity is insufficient.

It also suits sites where the power supply is unreliable or is interrupted from time to time. The battery backup keeps the unit running for eight hours without mains power.

The unit also works as a standalone device on sites that need no heat pumps at all. Typical applications are security-of-supply installations, temporary accommodation and infrastructure sites where an interruption would be costly.

The module has the same dimensions as the other Aurora Block units, so it is stacked and moved with the same equipment and needs no foundation of its own.

Aurora 64 oil boiler in two roles

Backup heat. When the outdoor temperature drops to about −25 °C or the power fails, the system starts the unit automatically, with no action from the user.

Peak power. During the coldest spells the unit produces extra capacity alongside the heat pumps, so heating output is sufficient in exceptional conditions too.

The unit is not used for cooling. That is handled by the air-to-water heat pump module or the ground-source module.

Aurora 64 oil boiler produces 90 °C water on HVO biodiesel or diesel

Aurora 64 oil boiler during a power outage

The unit’s own electrical demand is small: the supply is single-phase and the maximum power input 500 W. The battery backup lasts eight hours.

The Spine platform responds to a temperature drop and to a power outage automatically, so no manual intervention is required.

Arctic Warm reports over 99 % system reliability in active deployments, even during power outages.

Spine remote control and alarms

The unit is controlled and adjusted through the Spine platform. You see the fuel level, temperatures and device status in real time. A five-year Spine licence is included in the delivery.

Remote control reduces site visits and shortens response time when something goes wrong. Read more about Spine heating control.

Aurora 64 oil boiler – technical data

Device type Condensing oil boiler, backup heating unit
SKU 1050601002
Output capacity 64 kW
Efficiency 90–98 %
Fluid heating up to 90 °C
Fuel tank approx. 500 L (HVO compatible)
Electrical supply Single-phase
Max power input 500 W
Battery backup 8 hours
Dimensions (W x D x H) 1140 x 1440 x 1600 mm
Weight 450 kg (without fuel)
Structure Stainless steel piping and frame, self-venting circulation pump
Connection 2″ flange
Distribution Fan units or hydronic circuit
Control Spine platform, 5-year licence included

Aurora 64 oil boiler as a modular unit

Add the product to your quote request cart and ask for a quotation – we size the right configuration for your site.

Download the product sheet as a PDF

All technical data is also available as a one-page product sheet in PDF format. The sheet covers the key features, system integration and the full specification table. Download the PDF product sheet (Aurora 64)

Fuel and emissions

The fuel tank holds approximately 500 litres, and the unit runs on both diesel and HVO biodiesel. Running time depends on how large a share of the heat the unit produces.

Fuel is consumed only by the redundancy layer, keeping overall system CO₂ emissions over 90 % below conventional solutions. Finland’s national energy agency Motiva publishes background on renewable fuels and heating methods.

Condensing technology raises the efficiency to 90–98 %, so considerably more is drawn from the fuel than with an ordinary boiler.

Aurora Block modules chained together, with the backup heating unit included

Commissioning the unit

The unit is lifted into place, connected to the hydronic circuit with 2″ flange couplings and wired to a single-phase supply.

Heat is distributed through fan units or directly into a hydronic heating circuit. Settings are made in the Spine service.

The unit is part of the same modular system as the heat pumps, so it is stacked and moved in the same way.

Aurora Block backup heating unit installed on a construction site

Frequently asked questions

What is the output of the Aurora 64 oil boiler?

Output is 64 kW and the efficiency 90–98 % with condensing technology.

How hot is the water the unit produces?

Fluid heating reaches up to 90 °C, clearly higher than a heat pump can deliver.

How long does the unit run during a power cut?

The battery backup lasts eight hours. The unit’s own electrical demand is single-phase and at most 500 W.

What fuel does the unit run on?

Diesel or HVO biodiesel. The fuel tank holds approximately 500 litres.

Is the unit suitable for ground thawing?

Ground thawing has its own dedicated unit, the Aurora Frost trailer, whose heat production is based on the same condensing boiler.

Does the Aurora 64 oil boiler cool?

No. Cooling is handled by the Aurora 28 or Aurora 50 heat pump module.

What is the product code?

The SKU is 1050601002. Use it in quotation requests and spare part enquiries.

Does the unit start automatically?

Yes. The Spine platform starts it automatically when the temperature drops or the power supply fails.

Before requesting a quote you can calculate your site’s heating energy need with the heating energy calculator – it shows how many modules and which combination the site requires.

Request a quote for the Aurora 64 module

Add the Aurora 64 oil boiler to your quote request cart and send the request – we answer quickly. You can collect several modules in one cart. The full range is on the worksite heating page. If you want to ask something first, open the chat in the bottom right corner.

Technical information

Power

64 kW

Hyötysuhde

90–98 %

Nesteen lämmitys

90 °C

Polttoainesäiliö

500 l

Akkuvarmennus

8 h

Sähkösyöttö

1~

Suurin ottoteho

500 W

Measurements

1140 x 1440 x 1600 mm

Weight

450 kg

Liitäntä

2"

Tuotekoodi

1050601002