Fixed input floor distribution board 63A/125A/VM terminating
SKU:5000334/2Fixed input floor distribution board 63A/125A/VM terminating
Fixed-input floor distribution board with per-phase measurement. Terminating model, no chaining onward — emphasis on 32A outputs: 1×63A, 3×32A, 1×16A and 2×16A/230V.
Distribution center with fixed input and phase load measurement TSR 63/125A ver 2 is a floor distribution board with a fixed cable input, where per-phase meters show the current and voltage of each of the three phases. The meters also double as indicator lights that show current is reaching the phases.
Fixed input makes the board more reliable
A fixed input makes the board more reliable than a plug-connected board: the supply can’t be accidentally disconnected, stolen or moved. The board is versatile, since it can be fed with a fuse rated anywhere from 63–125A depending on what’s needed.
Emphasis on 32A outputs
Outputs include 1×63A, 3×32A, 1×16A and 2×16A/230V. Three 32A outputs make this board a particularly good choice when several medium-sized machines are used on site at the same time — for example mixers, compressors or heaters.
The final board in the chain
Unlike the base model, this board cannot chain power onward to another board — all power leaves through the socket outputs. Version 2 is therefore meant to be the last board in a line, once no further chaining is needed. On this model, the phase meters measure only the socket outputs.
Phase meters reveal unbalanced load instantly
Per-phase measurement helps you spot unbalanced load before it trips a fuse or causes a break in the site’s power distribution. Read here why and how phase measurement makes site operations more efficient.
A light aluminium body that travels well
Distribution center with fixed input and phase load measurement TSR 63/125A ver 2 is made of aluminium, so it’s light in construction. It’s easy to carry by its handle and hang on a wall or board stand from the hanging loops, or it can be set on the floor on its own feet.
Serviceable and customizable
The board is manufactured in Finland using only high-quality European components, such as PCE and Schneider. All parts are available as spare parts, and the board can be modified according to customer wishes — for example, the number and size of the boxes can be changed.
How version 2 differs from the other floor distribution boards
Version 2 is meant to be the last board in a chain — it cannot chain power onward. If you need a board you can chain onward from, see the base model or version 4.
Who this floor distribution board suits
Distribution center with fixed input and phase load measurement TSR 63/125A ver 2 suits large projects and sites in particular, where many boards are needed and this board serves as the last link in the chain, once sufficient power along the route has already been ensured with 125A cabling. The “floor” in this board’s category name doesn’t mean it has to be used per building floor — a “floor” can just as well be any area or point in the chain. The model also suits multi-storey sites where several medium-sized machines run at the same time and this board is the last one in the chain, with no need to continue onward.
Technical information
| Rated current | 125 A |
| Rated voltage | 400 V |
| RCD | 1 x 40A/30mA, 2 x 63/300mA |
| Outputs | 1×63A, 3×32A, 1×16A, 2×16A 230V |
| Fixed input | AL/CU 6-95mm² |
| Main switch | 125A |
| Enclosure rating | IP44 |
| Dimensions | 22×46×82 cm |
| Weight | 17.8 kg |
Add the product to the quote cart and request an offer – we’ll also confirm availability and delivery time.
Frequently asked questions
Can power be chained onward from version 2?
No, version 2 is the final board in the chain – all power leaves through the socket outputs. If you need a chainable model, see the base model or version 4.
Why does the board have three 32A outputs?
Three 32A outputs let you run several medium-sized machines at the same time from one board.
Can the board be customized to fit my needs?
Yes, the number and size of the boxes can be customized to the customer’s needs at our Finnish factory.
How is the board installed?
The board can be hung on a wall or board stand from the hanging loops, or placed on the floor on its own feet.
See also the full Subcenter with fixed connection range, or add Distribution center with fixed input and phase load measurement TSR 63/125A ver 2 to your quote cart now.
Technical information
| Nominal Current | 125 A |
|---|---|
| Nominal voltage | 400 V |
| RCD | 1 x 40A/30mA, 2 x 63/300mA |
| Weight | 17,8 kg |
| Measurements | 22x46x82 cm |
| Outlets | 1x63A, 3 x 32A, 1 x 16A, 2 x 16A 230V |
| Fuses | 1 x C16 3P |
| Fixed input | AL/CU 6-95mm2 |
| Main switch | 125A |
| Enclosure class | IP44 |
You may also like…
-
Fixed input floor distribution board 63A/125A/VM chaining 125A
Fixed-input floor distribution board with per-phase measurement. Board that can…
-
Subcabinet with fixed input TSR 63/125A Spine
Subcabinet with fixed input TSR 63/125A Spine comes with Spine…
-
Fixed input floor distribution board 63A/125A/VM fixed 32A + 63A outputs
Fixed-input floor distribution board with per-phase measurement. Two separate chain…
-
Fixed input floor distribution board 63A/125A/VM fixed 32A outputs
Fixed-input floor distribution board with per-phase measurement. One input cable,…