Fixed input floor distribution board 63A/125A/VM fixed 32A outputs
SKU:5000334/3Fixed input floor distribution board 63A/125A/VM fixed 32A outputs
Fixed-input floor distribution board with per-phase measurement. One input cable, three fixed 32A chain outputs via terminal blocks. Outputs: 2×32A, 1×16A and 6×16A/230V.
Subcabinet with phase load meters and fixed input TSR 63/125A ver 3 is a floor distribution board with a fixed cable input, where per-phase meters show the current and voltage of each of the three phases. The meters also double as indicator lights that show current is reaching the phases.
Fixed input makes the board more reliable
A fixed input makes the board more reliable than a plug-connected board: the supply can’t be accidentally disconnected, stolen or moved. The board is versatile, since it can be fed with a fuse rated anywhere from 63–125A depending on what’s needed.
One input cable, three chain outputs
The board has a single input cable, and can be chained onward through three fixed 32A outputs via terminal blocks. It also has outputs for 2×32A, 1×16A and 6×16A/230V, so the board is enough to feed several power tools and smaller machines from one point.
Phase meters reveal unbalanced load instantly
Per-phase measurement helps you spot unbalanced load before it trips a fuse or causes a break in the site’s power distribution. Read here why and how phase measurement makes site operations more efficient.
A light aluminium body that travels well
Subcabinet with phase load meters and fixed input TSR 63/125A ver 3 is made of aluminium, so it’s light in construction. It’s easy to carry by its handle and hang on a wall or board stand from the hanging loops, or it can be set on the floor on its own feet.
Serviceable and customizable
The board is manufactured in Finland using only high-quality European components, such as PCE and Schneider. All parts are available as spare parts, and the board can be modified according to customer wishes — for example, the number and size of the boxes can be changed.
How version 3 differs from the other floor distribution boards
If you also need a 63A output, see Subcabinet with fixed input and phase load measurement TSR 63/125A.
Who this floor distribution board suits
Subcabinet with phase load meters and fixed input TSR 63/125A ver 3 suits large projects and sites in particular, where many boards are needed and you want to ensure sufficient power with 125A cabling that continues, chained, through several lighter 32A outputs. The “floor” in this board’s category name doesn’t mean it has to be used per building floor — a “floor” can just as well be any area or point that power is chained onward to. The model also suits multi-storey construction sites, where power is distributed floor by floor with fixed cabling and load needs to be tracked per phase through the smaller 32A and 16A outputs.
Technical information
| Rated current | 125 A |
| Rated voltage | 400 V |
| RCD | 1 x 40A/30mA, 2 x 63/300mA |
| Outputs | 2 x 32A, 1 x 16A, 6 x 16A 230V |
| Fixed chaining | 3x 32A AL/CU 16mm² |
| Fixed input | AL/CU 6-95mm² |
| Main switch | 125A |
| Enclosure rating | IP44 |
| Dimensions (W×D×H) | 22×46×82 cm |
| Weight | 15 kg |
Add the product to the quote cart and request an offer – we’ll also confirm availability and delivery time.
Frequently asked questions
Can the boards be chained through several floors?
Yes, the board has a single input cable, and a fixed 3×32A AL/CU 16mm² chain runs through terminal blocks to the next floor distribution board.
Can the board be customized to fit my needs?
Yes, the number and size of the boxes can be customized to the customer’s needs at our Finnish factory.
How is the board installed?
The board can be hung on a wall or board stand from the hanging loops, or placed on the floor on its own feet.
See also the full Subcenter with fixed connection range, or add Subcabinet with phase load meters and fixed input TSR 63/125A ver 3 to your quote cart now.
Technical information
| Nominal Current | 125 A |
|---|---|
| Nominal voltage | 400 V |
| RCD | 1 x 40A/30mA, 2 x 63/300mA |
| Weight | 15 kg |
| Dimensions (W x D x H) | 22x46x82 cm |
| Outlets | 2 x 32A, 1 x 16A, 6 x 16A 230V |
| Fuses | 1 x C16 3P |
| Fixed chaining | 3x 32A AL/CU 16mm2 |
| Fixed input | AL/CU 6-95mm2 |
| Main switch | 125A |
| Enclosure class | IP44 |
Diagrams
You may also like…
-
Subcabinet with fixed input TSR 63/125A Spine
Subcabinet with fixed input TSR 63/125A Spine comes with Spine…
-
Fixed input floor distribution board 63A/125A/VM fixed 32A + 63A outputs
Fixed-input floor distribution board with per-phase measurement. Two separate chain…
-
Fixed input floor distribution board 63A/125A/VM chaining 125A
Fixed-input floor distribution board with per-phase measurement. Board that can…
-
Fixed input floor distribution board 63A/125A/VM terminating
Fixed-input floor distribution board with per-phase measurement. Terminating model, no…