Sub central FUC125X Spine for site cabins
Product code (SKU): 505010004Sub central FUC125X Spine for site cabins
The FUC125X Spine worksite electrical substation is specifically designed for powering and electrifying site offices and modular worksite cabins. This robust unit is equipped with 6 x 32A socket outlets, ideal for construction site cabins, along with 3 x 230V/16A industrial outlets to meet various site needs. The sub central features a large lockable door, securing the fixed cable supply and socket outlets from unauthorized access, ensuring a safe and reliable power source on the job site.
For ease of transportation and storage, the galvanized legs can be pushed inside the unit during transport and can be fully removed if necessary. The center also includes lifting loops and handles to assist with movement, while the frame is made from durable, powder-coated aluminium. The unit can be safely packed with 4 units per EUR pallet for efficient logistics.
The FUC125X comes standard with real-time remote monitoring via the Spine service. This feature allows you to easily monitor and report the energy consumption of the site cabins, as well as set proactive alerts for potential issues. Activation of the Spine service is quick and simple with a QR code, making it a seamless solution for managing power usage on construction sites.
Manufactured in Finland, the FUC125X Spine is a high-quality, reliable solution for the electrification of site offices and worksite cabins.
Sub central FUC125X Spine for site cabins is manufactured in Finland and fitted with a large lockable door, behind which the fixed cable supply and socket outlets are kept safe.
The board has 6 x 32 A socket outlets suited to powering site cabins, plus 3 x 230 V / 16 A Schuko outlets.
The stainless steel legs can be pushed into the board to save space during transport, and can be removed entirely if needed. The aluminium enclosure has lifting eyes and carrying handles to make it easier to move.
The board comes with Spine real-time remote monitoring as standard, letting you measure energy consumption and set up proactive alarms, among other things. Setting up the Spine service is quick and easy.

Sub central FUC125X Spine for site cabins – technical data
- Rated current: 125 A
- Rated voltage: 400 V
- Socket outlets: 6 x 32 A, 3 x 230 V / 16 A
- RCD: 300 mA
- Short-circuit rating: Icf = 17 kA
- Enclosure rating: IP44
- Dimensions (W x H x D): 92 x 80/115 x 34/60 cm
- Weight: 43.5 kg
Does this model suit your site? Add the product to the quote cart at the top of the page to get a quote.
Sub central FUC125X Spine for site cabins on the worksite
Spine is a remote monitoring system. Measurement data is sent to the cloud service where it can be viewed on any device – nobody needs to travel to the site to read a meter.
The service shows electricity consumption, load distribution between phases, voltage drop and CO₂ emissions, among others. Predictive alarms can be set so a deviation is caught before it stops the work.
The same cloud service gathers every Spine unit on the site into one view, however many measuring points there are.
This model is rated 125 A. Size the equipment by the actual simultaneous load – the sum of the nameplate ratings almost always leads to oversizing.
Outputs: 6 x 32 A, 3 x 230 V / 16 A. Count the work points before choosing – the number of outputs decides how many machines one board can feed.
Where Sub central FUC125X Spine for site cabins is used
Typical sites are construction projects, renovations, industrial maintenance and event power. What they share is that the electrical supply is temporary and the conditions are demanding.
Temporary does not mean lighter requirements. Site equipment is exposed to dust, moisture, moving and mechanical stress in a way that fixed installations never are.
Check the load distribution between phases during use. Uneven distribution overloads one phase while the others run half empty, and the usual symptom is a fuse that keeps tripping.
Sub central FUC125X Spine for site cabins – how to choose the right model
The equipment is chosen by rated current and outputs. Start by calculating the simultaneous load and the output types needed, and choose the model on that basis.
Other models of the same type are Spine Plug & Play 16A, Spine Plug & Play 32A, Spine Plug & Play 63A, Spine Plug & Play 125A, Spine for 16A-1250A centers with fixed input.
Other details that affect the choice: protection class IP44, short-circuit withstand Icf = 17 kA, RCD 300 mA, weight 43,5 kg, dimensions 92 x 80/115 x 34/60 cm. These are worth checking already at the quotation stage.
You can see the full range in the product group, and read about real-time monitoring on the Spine page.
Sub central FUC125X Spine for site cabins – practical notes for use
Winter brings requirements of its own. Condensation forms when cold equipment is brought into the warm, and moisture inside the enclosure is a common reason for an RCD tripping with no visible cause.
Mark the equipment with the site details and keep a record of what is fed from where. On a site with several contractors that saves time at every fault-finding.
RCD protection is mandatory for socket outputs on a site. Its operation is tested with the test button at commissioning and at regular intervals afterwards.
Sub central FUC125X Spine for site cabins – installation and maintenance
Installation and connection work is carried out by a qualified electrician. The equipment must be made dead before connection work, and the absence of voltage verified by measurement.
Place the equipment on level ground and so that it can be reached freely even when the site fills up with material. Material stacked in front blocks both use and emergency isolation.
Test the RCD with its test button at commissioning and at regular intervals afterwards. The test takes a second and is still almost always forgotten.
The unit weighs 43,5 kg. Take the weight into account when moving and lifting – damage is most often caused during transport, not in use.
Check the joints and fixings regularly during use. A joint that heats up is a sign of a fault and should be corrected before the fault spreads.
Safety and inspections
Site electrical installations are subject to the same requirements as fixed installations, and some of them are stricter. The equipment has to withstand moving, dust, moisture and mechanical stress for the whole project.
The installation is inspected at commissioning and regularly during use: enclosure, joints, the operation of the protective devices and the fact that live parts cannot be reached.
Damaged equipment is not repaired improvised on site. A cracked enclosure, a burnt terminal or a damaged socket is replaced – on a site a temporary repair almost always becomes permanent.
Document the configuration and any changes made. Up-to-date information on outputs and protection speeds up fault-finding and the next inspection.
Delivery and sizing help
We deliver the equipment together with the cables and the rest of the site power supply in one delivery, so the set is complete when it arrives on site.
Describe the whole site in your request for quotation: supply power, the outputs needed and the estimated length of the project. We size the set on that basis.
Use the product number 505010004 when ordering and when asking about spare parts. It identifies this exact model, which matters when the same series comes in several sizes.
We also help with the sizing. If you are unsure about the size or the number of outputs, ask us – equipment sized wrong costs more than equipment chosen right the first time.
Frequently asked questions
How many socket outlets does the sub central have?
The board has 6 x 32 A socket outlets for powering site cabins, plus 3 x 230 V / 16 A Schuko outlets.
Can the legs be removed for transport?
Yes. The stainless steel legs can be pushed into the board to save space during transport, and can be removed entirely if needed.
Does the board include Spine remote monitoring?
Yes, Spine real-time remote monitoring is included as standard, letting you measure energy consumption and set up proactive alarms.
What is the product’s part number?
The part number is 505010004. You can use it for orders and quote requests.
Didn’t find the answer to your question? Add the product to the quote cart and our sales team will help — or open the chat in the bottom-right corner of the page.
Does the product have an RCD?
Residual current device (RCD): 300 mA.
What is the protection class?
Protection class: IP44.
What is the short-circuit withstand?
Short-circuit withstand: Icf = 17 kA.
What are the dimensions?
Dimensions: 92 x 80/115 x 34/60 cm.
How much does the product weigh?
Weight: 43,5 kg.
Do several measuring points appear in one view?
Yes. The same cloud service gathers all Spine units on the site into one view.
What is the product number?
The product number is 505010004. Use it in requests for quotation and spare part enquiries.
Who may install the product?
Installation is carried out by a qualified electrician. The requirements are explained in more detail on the Tukes website.